4-1
4
Initial Startup of the Access Controller Module
Setting Up a Configuration Environment
Set up a configuration environment by connecting the console port of the LSQM1WCMB0 access
controller module to a console terminal, a PC in this example, as shown in Figure 4-1.
Figure 4-1
Set up a network connection for LSQM1WCMB0 configuration
Connecting the Console Cable
1) Connect the DB-9 female connector of the console cable to the serial port of the PC.
2) Connect the RJ-45 connector of the console cable to the console port of the LSQM1WCMB0.
Setting Terminal Parameters
Before configuring your access controller module through a console terminal, a PC running Microsoft
Windows XP for example, you need to set the parameters for the console terminal as follows:
z
Bits per second: 9600
z
Data bits: 8
z
Parity: none
z
Stop bits: 1
z
Flow control: none
z
Terminal emulation: VT100 or Auto detect.
Follow these steps to set the parameters:
1) Start the computer and select
Start
>
Programs
>
Accessories
>
Communications
>
HyperTerminal
. The
Connection Description
dialog box appears, as shown below.