background image

 

3-24 

 

NOTE: 

To access the EXTENDED-BOOTWARE menu, press 

Ctrl

 + 

B

 within four seconds at the 

prompt "Press Ctrl+B to access EXTENDED-BOOTWARE MENU." If you do not press 

Ctrl

+

B

 at the prompt, the system starts to read and decompress program files. To enter the 

EXTENDED-BOOT menu afterwards, you need to reboot the firewall. 

 

Logging in to the firewall 

You can use the following methods to access and manage the firewall. For more information about 
logging in to the firewall, see the configuration guides and command references for the firewall. 

 

Logging in from the Web interface 

 

Logging in from the serial console port or micro USB console port 

 

Logging in through Telnet 

Logging in from the Web interface 

 

IMPORTANT: 

After accessing the Web interface with the default account, modify the password of the default 
account or create a new administrator account and delete the default account as a best practice. 

 

At the first login from the Web interface, you can use the default account or use an account created 
from the CLI. 

The default Web interface login information is as follows: 

 

Username

—admin 

 

Password

—admin 

 

IP address of the management Ethernet port (MGMT)

—192.168.0.1/24 

To log in to the firewall from the Web interface by using the default account: 

1. 

Use an Ethernet cable to connect a PC to the management Ethernet port on the firewall. 

2. 

Configure an IP address in subnet 192.168.0.0/24 for the PC. Make sure the PC and the firewall 
are reachable to each other. 

The PC must use a different IP address than the management Ethernet port. 

3. 

Start a browser, enter 

192.168.0.1

 in the address bar, and press 

Enter

4. 

Enter the default username 

admin

 and password 

admin 

and then click 

Login

Logging in from the serial console port or micro USB console 
port 

To log in from the serial console port or micro USB console port, see "

Setting up the configuration 

environment and configuring terminal parameters

." 

Logging in through Telnet 

1. 

Connect your PC to the serial console port or micro USB console port on the firewall, and 
enable the Telnet function in system view by using the 

telnet server enable

 command. 

2. 

Enter VTY user line view, and configure the authentication mode, user role, and common 
properties in VTY user line view. 

Содержание F5000-AI160

Страница 1: ...necting Ethernet cables 17 Connecting a fiber port 17 Connecting power cords 20 Connecting an AC power cord 20 Connecting a DC power cord 20 Verifying the installation 21 3 Accessing the firewall 3 22...

Страница 2: ...Chassis views and technical specifications 7 38 Chassis views 7 39 Power supplies 7 40 AC power supplies 7 40 DC power supplies 7 40 Fan trays 7 41 Dimensions and weights 7 41 Chassis 7 41 Drives 7 4...

Страница 3: ...afety recommendations Do not place the firewall on an unstable case or desk The firewall might be severely damaged in case of a fall Make sure the ground is dry and flat and anti slip measures are in...

Страница 4: ...ansceiver modules to avoid damage caused by built up dust Insert a dust plug into empty fiber ports Handling safety When you move the firewall follow these guidelines Move and unpack the firewall care...

Страница 5: ...ls and significantly lower the reliability and lifespan of the firewall For the temperature and humidity requirements of the firewall see Table1 1 Table1 1 Temperature humidity requirements Temperatur...

Страница 6: ...prevent electrostatic discharge ESD follow these guidelines Make sure the firewall the workbench and the rack are reliably grounded Take dust proof measures for the equipment room For more information...

Страница 7: ...f the chassis is reliably grounded Make sure the grounding terminal of the AC power receptacle is reliably grounded Install a lightning arrester at the input end of the power supply to enhance the lig...

Страница 8: ...ating 0 C to 45 C 32 F to 113 F Storage 40 C to 70 C 40 F to 158 F Relative humidity Operating 5 RH to 95 RH noncondensing Storage 5 RH to 95 RH noncondensing Cleanness Dust concentration 3 10 4 parti...

Страница 9: ...ocate the power switch in the equipment room In case of emergency during operation switch off the power switch Rack mounting requirements Make sure the rack is equipped with a good ventilation system...

Страница 10: ...efore installation make sure the firewall and rack are grounded correctly and you wear an ESD wrist strap 5 Installing a fan tray Install compatible fan trays on the firewall 6 Installing a power supp...

Страница 11: ...damage use a minimum of two persons to rack mount the firewall CAUTION As a best practice use slide rails together with the mounting brackets to support the weight of the chassis To install the firewa...

Страница 12: ...h the wide flange inside or outside the rack Table2 2 Installation methods of rear mounting brackets Distance between the front and rear rack posts Rear mounting bracket installation method 421 to 556...

Страница 13: ...2 4 Attaching the rear mounting brackets to the rear rack posts with the wide flange inside the rack Figure2 5 Attaching the rear mounting brackets to the rear rack posts with the wide flange outside...

Страница 14: ...cure the mounting brackets to the front rack posts and make sure the shoulder screws rest firmly on the upper edge of the rear mounting brackets Figure2 6 Mounting the firewall in the rack with the wi...

Страница 15: ...wall in one of the following ways depending on the grounding conditions available at the installation site Grounding the firewall with a grounding strip If a grounding strip is available at the instal...

Страница 16: ...unding point on the rack Figure2 9 Grounding the firewall with the grounding terminal on the rack Installing a fan tray CAUTION The firewall comes with the six fan tray slots empty To ensure good vent...

Страница 17: ...wer supplies on the same firewall Before installing a power supply make sure the power supply is powered off and the grounding cable is correctly connected No power supplies are provided with the fire...

Страница 18: ...s are hot swappable Install a filler panel in empty drive slots to prevent dust and ESD damage IMPORTANT The firewall does not come with any drives and cannot recognize drives from other vendors Purch...

Страница 19: ...ecting a fiber make sure the optical power at the receiving end does not exceed the transceiver module s upper threshold of the optical receive power If the optical power at the receiving end exceeds...

Страница 20: ...dule with an LC port To connect the firewall to the network through an optical fiber 1 Remove the dust plug from the fiber port 2 Pull the bail latch on the transceiver module upwards Skip this step i...

Страница 21: ...htly until it clicks into place MPO connector Orient the connector with the white dot on it facing right Insert the connector horizontally into the transceiver module Push the connector into the trans...

Страница 22: ...er cord Connecting a DC power cord 1 Use a screwdriver to loosen the screws on the protection cover over the power receptacle and then remove the cover 2 Correctly orient the DC power cord connector w...

Страница 23: ...sure correct installation There is enough space for heat dissipation around the firewall The firewall and its components are installed securely The screws are fastened tightly The power source specifi...

Страница 24: ...se programs Bits per second 115200 Data bits 8 Stop bits 1 Parity None Flow control None Starting the firewall Pre start checking WARNING Locate the emergency power off switch in the room before power...

Страница 25: ...l H3C F5000 AI160 BootWare Version 1 03 Copyright c 2004 2021 New H3C Technologies Co Ltd Compiled Date Dec 1 2021 15 53 04 Memory Type DDR4 SDRAM Memory Size 32768MB SPI Flash Size 32MB EMMC Flash Si...

Страница 26: ...CLI The default Web interface login information is as follows Username admin Password admin IP address of the management Ethernet port MGMT 192 168 0 1 24 To log in to the firewall from the Web inter...

Страница 27: ...word are admin 3 Specify an IP address for the network port of the PC and make sure the PC and the firewall are reachable to each other The IP address of management Ethernet port MGMT is 192 168 0 1 2...

Страница 28: ...e from the power cord and then remove the power cord connector from the power supply 2 Hold the power supply handle with one hand press the latch towards the handle and then pull the power supply part...

Страница 29: ...e Storage settings page 2 Execute the umount command from the CLI to unmount all the file systems 3 Pull the drive slowly out of the slot along the guide rails 4 Wait for 30 seconds and insert the new...

Страница 30: ...own in Figure4 5 3 Pull down the bail latch on the transceiver module to the horizontal position Skip this step if the bail latch is plastic 4 Hold the bail latch to pull the transceiver module slowly...

Страница 31: ...0 CPLD_A 2 0 CPLD_B 2 0 CFCard Num 0 Displaying software and hardware version information for the firewall Use the display version command to display software and hardware version information for the...

Страница 32: ...anuinfo command to display the electrical label information for the firewall Sysname display device manuinfo Slot 1 CPU 0 DEVICE_NAME F5000 AI160 DEVICE_SERIAL_NUMBER 210235A2QA000010077 MAC_ADDRESS 0...

Страница 33: ...ption Field Description DEVICE_NAME Firewall name DEVICE_SERIAL_NUMBER Firewall serial number MAC_ADDRESS MAC address of the firewall MANUFACTURING_DATE Manufacturing date of the firewall VENDOR_NAME...

Страница 34: ...Memory usage information Total Total size of the physical memory space that can be allocated The memory space is virtually divided into two parts Part 1 is used for kernel codes kernel management and...

Страница 35: ...is not supported in the current software version Displaying the operational status of fan trays Use the display fan command to display the operational status of fan trays Sysname display fan SLOT 1 Fa...

Страница 36: ...on Sensor Temperature sensor inflow Air inlet vent temperature sensor outflow Air outlet vent temperature sensor hotspot Hotspot temperature sensor Temperature Current temperature LowerLimit Low tempe...

Страница 37: ...e display diagnostic information Save or display diagnostic information Y save N display Y N n display cpu Slot 1 CPU 0 CPU usage 13 in last 5 seconds 13 in last 1 minute 13 in last 5 minutes Displayi...

Страница 38: ...owing methods Use the reboot command to reboot the firewall immediately Enable the scheduled reboot function at the CLI You can set a time at which the firewall can automatically reboot or set a delay...

Страница 39: ...ue 1 Verify that the power supply system is operating correctly 2 Verify that the serial console cable or micro USB console cable is correctly connected 3 Verify that the serial console cable or micro...

Страница 40: ...nt 5 If the issue persists contact your local sales agent Software loading failure Symptom Software loading fails and the system runs the software of the previous version Solution To solve the issue 1...

Страница 41: ...hernet port MGMT 5 LEDs 6 Micro USB port 7 Reset button 8 USB port 9 Console port CONSOLE 10 BMC network port reserved 11 System power button 12 HA ports The reset button resets the firewall but does...

Страница 42: ...two power supplies for the firewall make sure they are the same model For the power supply specifications see Power supply specifications AC power supplies The PSR650B 12A1 power supply provides a ma...

Страница 43: ...firewall is fully configured with fan trays Figure7 5 LSPM1FANSB fan tray 1 Handle 2 Alarm LED Dimensions and weights The weight of the firewall includes the chassis and its removable components Chass...

Страница 44: ...tion 208 W Maximum power consumption 390 W Drives Table7 6 Drive power consumption Drive model Power consumption NS SSD 480G SATA M 2 4 5 W Power supply specifications Table7 7 AC power supply specifi...

Страница 45: ...andard compliant RS 232 Baud rate 9600 bps to 115200 bps default Cable type Common asynchronous serial port cable Transmission distance 15 m 49 21 ft Services Connection to an ASCII terminal Connectio...

Страница 46: ...5 Table7 14 GE fiber port specifications Item Specification Connector type LC Transceiver module type SFP Standard compliance 1000BASE X Interface speed 1000 Mbps Duplex mode Full duplex Table7 15 100...

Страница 47: ...5 to 5 22 to 3 SFP GE LH40 SM1550 4 to 1 21 to 3 SFP GE LH80 SM1550 4 to 5 22 to 3 SFP GE LH100 SM1550 0 to 5 30 to 9 10 GE fiber port Table7 17 10 GE fiber port specifications Item Specification Con...

Страница 48: ...8 2 to 0 5 14 4 to 0 5 SFP XG LX SM1310 D 10 31 Gbps 8 2 to 0 5 14 4 to 0 5 SFP XG LH40 SM1550 10 31 Gbps 4 7 to 4 15 8 to 1 SFP XG SX MM850 D 10 31 Gbps 7 3 to 1 9 9 to 0 5 40 GE fiber port QSFP tra...

Страница 49: ...R Interface speed LAN PHY 40 Gbps Table7 24 Specifications of QSFP transceiver modules with LC connectors 1 Transceiver module Central wavelength nm Fiber mode Fiber diameter m Mode bandwidth MHz km T...

Страница 50: ...pe QSFP28 Standard compliance 100GBASE R Interface speed LAN PHY 100 Gbps Table7 27 Specifications of QSFP28 transceiver modules with MPO connectors 1 Transceiver module Central wavelength nm Fiber mo...

Страница 51: ...M1300 Four lanes 1295 56 1300 05 1304 58 1309 14 SMF 9 125 N A 10 km 6 21 miles QSFP 100G ER4L WDM1 300 Four lanes 1295 56 1300 05 1304 58 1309 14 SMF 9 125 N A 40 km 24 86 miles Table7 31 Specificati...

Страница 52: ...iled excluding the resetting period Flashing at 0 5 Hz The system is operating correctly Flashing at 4 Hz The system is starting or loading software On The system has failed Power supply status LEDs P...

Страница 53: ...itializing Slow flashing yellow and green A general alarm has occurred Slow flashing yellow A severe alarm has occurred System power LED Steady green The system has started Slowing flashing green The...

Страница 54: ...ble Table9 2 Micro USB console cable pinouts USB Type A connector Signal USB Type mini A B connector Signal 1 VBUS 1 VBUS 2 D 2 D 3 D 3 D 4 ID NC 4 GND 5 GND Ethernet twisted pair cable Introduction A...

Страница 55: ...nt information from being listened and eliminate external electromagnetic interference EMI of external sources STPs have strict application requirements and are expensive although they provide better...

Страница 56: ...Pin 10BASE T 100BASE TX 1000BASE T Signal Function Signal Function 1 Tx Sends data BIDA Bi directional data cable A Straight through cable white orange orange white green blue white blue green white b...

Страница 57: ...a cable C To ensure normal communication the pins for sending data on one port must correspond to the pins for receiving data on the peer port When both of the ports on the two devices are MDI or MDIX...

Страница 58: ...t source and transmission distance Uses lasers as the light source often within campus backbones for distance of several thousand meters Uses LEDs as the light source often within LANs or distances of...

Страница 59: ...two fiber connectors You can brush the end faces only in one direction Never bend or curve a fiber when connecting it If the fiber has to pass through a metallic board hole when passing through a met...

Отзывы: