DO NOT DIVE.
Swim spa Controls
Utilities – GFCI Test Feature
124
DO NOT DIVE.
The Ground Fault Circuit Interrupter (GFCI) or Residual Current Detector (RCD) is an important
safety device and is required equipment on a hot tub installation.
Forcing the GFCI Trip Test (North America Only)
Touching the GFCI Test Icon on the Utilities Screen takes you to the GFCI Test screen. This feature
is not available on all systems. The GFCI Test icon will only display if the system is capable of this
feature.
The installer can use the GFCI Trip Test to confirm proper function of the GFCI.
The GFCI should trip within several seconds and the swim spa should shut down. If it does not, shut
down the power and manually verify that a GFCI breaker is installed and that the circuit and swim
spa are wired correctly. Verify the function of the GFCI with its own test button. Restore power to
the swim spa and repeat the GFCI Trip Test.
Once the GFCI is tripped by the test (causing the swim spa to be shut off from power being
removed), reset the GFCI breaker to turn swim spa back on. You can verify a successful test by
navigating to the above screen. “Passed” should appear after the Reset line is selected on the GFCI
screen.
CE Product:
CE registered systems do not have an RCD Test Feature due to the nature of the electrical service.
Some UL registered systems do not have the GFCI Test Feature. The end-user must be trained how
to properly test and reset the RCD.