background image

WARNING & SAFETY INSTRUCTIONS 

 

 

Page 3 

 

 

Before  you  begin the installation  of the appliance, we advise you read 
and carefully follow the instructions contained in this manual. It contains 
important information about safety, installation, use and maintenance of 
the product. The actual system that you have received, may differ from 
the pictures/illustrations/descriptions in this Technical Manual. 

 

 

Failure to follow the instructions could cause personal injury or damage 
to  the  appliance  or  property.  Only  when  installed,  commissioned  and 
serviced correctly, the appliance will offer you many years of trouble-free 
operation. 

 

 

The appliance is intended to 'soften' the water, meaning it will remove 
hardness  minerals;  it  will  not  necessarily  remove  other  contaminants 
present in the water. The appliance will not purify polluted water or make 
it safe to drink! 

 

 

Installation of the appliance should only be undertaken by a competent 
person,  aware  of  the  local  codes  in  force.  All  plumbing  and  electrical 
connections must be done in accordance with local codes. 

 

 

Before setting up the appliance, make sure to check it for any externally 
visible damage; do not install or use when damaged.  

 

 

Use  a  hand  truck  to  transport  the  appliance.  To  prevent  accident  or 
injury,  do  not  hoist  the  appliance  over  your  shoulder.  Do  not  lay  the 
appliance on its side.  

 

 

Keep this Technical Manual in a safe place and ensure that new users are 
familiar with the content.  

 

 

The appliance is designed and manufactured in accordance with current 
safety  requirements  and  regulations.  Incorrect  repairs  can  result  in 
unforeseen danger for the user, for which the manufacturer cannot be 
held  responsible.  Therefore  repairs  should  only  be  undertaken  by  a 
competent technician, familiar and trained for this product. 

 

 

In respect  of the environment, this appliance should be disposed  of  in 
accordance  with  Waste  Electrical  and  Electronic  Equipment 
requirements. Refer to national/local laws and codes for correct recycling 
of the appliance. 

 

 

Содержание H2O-CS-ECO

Страница 1: ... 2017 erie water treatment TM EN H2O CS ECO Rev2017 03 Technical Manual WATER SOFTENER Models H2O CS ECO ...

Страница 2: ...missioning Page 6 Electronic control panel Page 7 Maintenance Page 11 Hydraulic flow diagram Page 12 Troubleshooting Page 14 Electrical wiring diagram Page 16 Default configuration parameter settings Page 17 Exploded view System Page 18 Exploded view Valve body assembly Page 20 Exploded view Valve head Timer assembly Page 22 Technical data Page 23 ...

Страница 3: ...e undertaken by a competent person aware of the local codes in force All plumbing and electrical connections must be done in accordance with local codes Before setting up the appliance make sure to check it for any externally visible damage do not install or use when damaged Use a hand truck to transport the appliance To prevent accident or injury do not hoist the appliance over your shoulder Do n...

Страница 4: ...nsiderably higher than day time water pressure install a pressure reducer ahead of the appliance if necessary OPERATING TEMPERATURE MIN MAX 2 65 C 35 149 F do not install the appliance in an environment where high ambient temperatures e g unvented boiler house or freezing temperatures can occur the appliance cannot be exposed to outdoor elements such as direct sunlight or atmospheric precipitation...

Страница 5: ...seals Tighten the nuts firmly by hand 2 Screw the connection kit with nuts onto the factory bypass make sure to install the gasket seals Tighten the nuts firmly by hand 3 Connect the mains water supply to the adaptor on the inlet port of the factory bypass 4 Connect the application to the adaptor on the outlet port of the factory bypass WITH 3 VALVE BYPASS SYSTEM not included Picture 4 inlet of ap...

Страница 6: ...tion close the tap 7 Check the appliance and all hydraulic connections for leaks After the first regenerations of the appliance some slight discoloration of the treated water might occur This is totally harmless and will disappear rapidly BRINE CABINET 1 Add water conditioner salt to the brine cabinet ELECTRONIC CONTROL PANEL 1 Program the electronic controller ADJUSTMENT RESIDUAL HARDNESS WITH FA...

Страница 7: ...ile the appliance will continue to operate normally it is recommended to have preventive maintenance performed by a professional To reset the maintenance reminder simply access the configuration parameters programming mode SERVICE MODE In service mode the display shows the time of day and the remaining capacity REGENERATION MODE In regeneration mode the display shows the actual regeneration cycle ...

Страница 8: ...offer optimal performance in a wide range of applications and situations See table at the end of this manual for default configuration parameter settings Before entering the programming mode make sure that the appliance is in service mode In case no button is pressed in a period of 5 min the control panel will automatically return to the service mode any changes made will NOT be saved 1 Press the ...

Страница 9: ...roll button again the display will show only when the regeneration mode was set to Dlyd or Dlyd Immd Press the up or down button to set the reserve capacity Variable the reserve capacity is calculated automatically based on the registered daily water usage Fxd press the scroll button again and press the up or down button to set the reserve capacity to a fixed amount 11 Press the scroll button agai...

Страница 10: ...of days since last regeneration In Srvc total number of days in service of Regens number of regenerations since installation TotVol total volume of treated water since installation LastSet number of days since last change of configuration parameter or hardness of incoming untreated water InstFlow instantaneous flow rate through appliance AvgVol calculated average daily water usage LastRgn consumed...

Страница 11: ...9 c MAINTENANCE POSITION inlet valve to appliance is OPEN outlet valve from appliance is CLOSED WITH 3 VALVE BYPASS SYSTEM not included Picture 10 a SERVICE POSITION bypass valve is CLOSED inlet valve to appliance is OPEN outlet valve from appliance is OPEN Picture 10 b BYPASS POSITION bypass valve is OPEN inlet valve to appliance is CLOSED outlet valve from appliance is CLOSED Picture 10 c MAINTE...

Страница 12: ...s in any device plumbed in in your water distribution system a proliferation of bacteria is possible especially in case of stagnant water Therefore this appliance is equipped with a days override feature that will automatically rinse the resin bed periodically even in case of low or absence of water usage If the power supply to the appliance is disconnected for a longer period of time we recommend...

Страница 13: ...HYDRAULIC FLOW DIAGRAMS Page 13 SERVICE REFILL BRINE PREP BRINE DRAW SLOW RINSE SERVICE REFILL BRINE PREPARATION BRINE DRAW SLOW RINSE ...

Страница 14: ...essive water in brine cabinet Improper brine draw Refer to problem Improper brine draw Improper setting of refill cycle Verify setting of refill cycle Missing refill flow control Verify that refill flow control is installed and properly sized Leak from control valve to brine cabinet Clean or replace plunger and solenoid diaphragm of refill solenoid Check seal between brine draw check ball and brin...

Страница 15: ...estrictor Clean injector and or brine draw restrictor Plugged injector filter Clean injector filter Restricted drain line Verify drain line for kinks or restrictions Restricted brine line Verify brine line for kinks or restrictions Leak in brine line Verify brine line and connections for air leakage No water in brine tank Refer to problem Control valve fails to refill brine tank ...

Страница 16: ...ELECTRICAL WIRING DIAGRAM Page 16 flow meter power lead auxilliary contact 24 VAC max 500mA refill solenoid white drain solenoid key pad ...

Страница 17: ... 2 BRINE PREPARATION min 15 15 15 15 Cycle 3 BRINE DRAW SLOW RINSE min 45 50 75 110 Regen Dlyd Immd Dlyd Immd Dlyd Immd Dlyd Immd Regen 2 00 2 00 2 00 2 00 Rsrv Variable Variable Variable Variable Auxilliary contact Regen Regen Regen Regen 1 When the Hardness Unit is changed in the Basic Settings the Exchange capacity per liter resin is automatically converted to the new Hardness Unit 2 When the E...

Страница 18: ...EXPLODED VIEW SYSTEM Page 18 ...

Страница 19: ...oT plug 10 39040 Cover 11 38547 Screw rivet 2x 12 39041 Salt lid 13 H1015 2 Brine line polytube to be ordered per meter 14 DM A6EU6 Quick fit elbow 3 8 15 38560 Plastic cap 16 74269 Air check assembly to be cut to length 17 38522 Drain hose to be ordered per meter 18 74163 Air gap with double hose barb 19 74174 Clamp drain hose 4x 20 39009 Cabinet body micro 9L 39080 Cabinet body mini 12L 39011 Ca...

Страница 20: ...EXPLODED VIEW VALVE BODY ASSEMBLY Page 20 ...

Страница 21: ...Spring clip 25 186 118 O ring brine plug 26 541 273 Brine plug 27 72467 Union gasket 2x 28 72542 Elbow inlet 29 19 19 Clip drain flow adjuster 30 186 134 O ring drain flow adjuster 2x 31 541 238 Drain flow adjuster 32 529 244 O ring drain port 33 467 216 Seal body stem 34 72605 Body stem 35 185 024 1 O ring seat insert small 36 541 204 Seat insert 37 185 029 1 O ring seat insert large 38 72602 Mai...

Страница 22: ...3 Drain solenoid 7 74019 Gasket drain solenoid 8 74016 Drain line adaptor 9 74018 Nut drain solenoid 10 185 115 1 O ring drain line adaptor 11 15 87 Screw valve head 4x 12 72216 Valve head 13 74262 Screw timer housing 2x Standard metric thread ISO 14 74189 Timer mounting bracket 15 28 8 28 Strain relief 2x 16 74026 PCB housing back 17 15 102 Screw PCB 2x 18 72788 Printed Circuit Board 19 74230 PCB...

Страница 23: ...1 4 Recommended maximum service flow m hr 4 0 9 1 2 1 8 2 6 Salt usage per regeneration kg 5 1 1 1 5 2 3 3 3 Rinse water usage per regeneration Ltr 5 49 54 82 120 3 Indicative numbers performances depending on operating conditions and water quality 4 Flow rate at which softening process is still executed adequately 5 Maximum salt water usage as brining is proportional minimum of 60 Dimensions weig...

Страница 24: ...Manufactured Assembled by erie water treatment a division of Aquion Inc www eriewatertreatment com ...

Отзывы: