Installation of the transducers 

Proper installation of the transducers is crucial for the effectiveness of the system. 

The transducers need to be placed at 1/3 and 2/3 of the length of the hull. 

Identify a suitable location for the transducers: 

Direct to the inside the hull (not on insulation or other material) 

Spot with min. diameter of 75 mm 

Even surface 

1. Use a sanding machine to remove all paint and make the spot as smooth/even as possible 

2. Clean the spot and the vibrating membrane of the transducer thoroughly with acetone or a similar cleaning product. Do 

not touch these surfaces after cleaning. If you accidentally did, clean again! 

3.

Apply the glue generously on the transducer membrane, making sure that the entire surface is evenly covered. The film of 
glue should be sufficiently thick to absorb all possible unevenness of the spot you have prepared for the transducer. You 
do not need to cover the threaded hole in the transducer membrane. Make sure that no air bubbles can develop between 
the membrane of the transducer and the surface on which it is glued

  

4. Place the transducer on the surface immediately after applying the glue (the glue hardens very quickly) 

5. Press the transducer slightly, making sure the glue has completely spread out, filling all possible air gaps and absorbing any 

unevenness of the steel on which the transducer is glued. You should see a little glue coming out from under the 
transducer all around  

6. Do not remove the glue that came out from under the transducer surface. The Loctite 3090 hardens in 2 minutes. However, 

for the glue to completely cure allow 24 hours. Hence, 

wait 24 hours before activating the transducer

 

7. If the transducer is installed in a location where it can be exposed to seawater, lubricants or cooling liquid, you can protect 

the glue with a marine kit. We recommend TEC 7. After installing the transducer, apply a seam of kit all around the juncture 
of the transducer, sealing off contact between the glue surface and any liquids. 

H2O Marine B.V. 

Burg. Loeffplein 70E, Office 32, 5211 RX, ’s-Hertogenbosch  -  The Netherlands  -  +31 (0)85 060 2837  -  www.h2o-marine.com  -  [email protected] 

Содержание Marine SonicShield P20-100-12 Volt

Страница 1: ...1 P20 100 12 Volt Installation guide H2O Marine B V Burg Loeffplein 70E Office 32 5211 RX s Hertogenbosch The Netherlands 31 0 85 060 2837 www h2o marine com info h2o marine com ...

Страница 2: ...Clean and dry Well ventilated Ambient temperature of 10 C 14 F and 50 C 122 F Protected from airborne particulate moisture and dirt Mount the control unit using the 4 holes underneath the holes for the screws of the lid Connect the control box to a 12 Volt DC power outlet Watch polarity On the big Techno connector the terminal number 1 is positive and the terminal number 3 is negative The electron...

Страница 3: ...hat no air bubbles can develop between the membrane of the transducer and the surface on which it is glued 4 Place the transducer on the surface immediately after applying the glue the glue hardens very quickly 5 Press the transducer slightly making sure the glue has completely spread out filling all possible air gaps and absorbing any unevenness of the steel on which the transducer is glued You s...

Страница 4: ... green switch activates 12 V DC to the power boards The blue signal lamps indicate the power circuit board PCB actuation Product overview outside Transducers H2O Marine B V Burg Loeffplein 70E Office 32 5211 RX s Hertogenbosch The Netherlands 31 0 85 060 2837 www h2o marine com info h2o marine com ...

Страница 5: ...act H2O Marine BV Burgemeester Loeffplein 70E 5211 RX s Hertogenbosch info h2o marine com 31 0 85 060 2837 H2O Marine B V Burg Loeffplein 70E Office 32 5211 RX s Hertogenbosch The Netherlands 31 0 85 060 2837 www h2o marine com info h2o marine com ...

Отзывы: