background image

www.h2fl ow.net  

  Tel: 888-635-0296 (Toll Free)  

OR

  (+1) 419-841-7774 (International)

6

Dimensions

DIMENSIONS

B

C

A

F

D

D

E

DIMENSION

VALUE

A

6.5”

B

5.875”

C

Schedule 40 - 1.5”

D

1.375”

E

4.63”

F

3.75”

WEIGHT

1.5 lbs

Models:

 FV-C-15 / FV-C-15-L

DIMENSION

VALUE

A

6.5”

B

5.875”

C

Schedule 40 - 2” (Slip) & 2.5” (with coupling)

D

1.375”

E

4.63”

F

3.75”

WEIGHT

1.5 lbs

Models:

 FV-C / FV-C-L / FV-C-S / 

FV-C-S-L / FV-C-Saline

ENGLISH/S

TAND

ARD

ENGLISH/S

TAND

ARD

DIMENSION

VALUE

A

165.1 mm

B

149.23 mm

C

Schedule 40 - DN40

D

34.93 mm

E

117.6 mm

F

92.25 mm

WEIGHT

0.544 kg

Models:

 FV-C-L-DN40

METRIC

DIMENSION

VALUE

A

165.1 mm

B

149.23 mm

C

Schedule 40 - DN50 (Slip) / 65 (with coupling)

D

34.93 mm

E

117.6 mm

F

92.25 mm

WEIGHT

0.544 kg

Models:

 FV-C-L-DN50/65

METRIC

Содержание FlowVis FV-3

Страница 1: ...ows orientation in any position e g horizontal vertical or even upside down Long life without sticking floats or paddle wheels Combined Flow Meter and Check Valve in all models except FV C S FV C Saline FV 3 FV L DN80 FV 4 and FV L DN100 CONCEPT As flow increases the check valve or safety flapper moves forward toward its fully open position The flapper s angular position is directly related to flo...

Страница 2: ... FV C S FV C Saline FV 3 FV L DN80 FV 4 and FV L DN100 1 x pivot pin For all other parts please contact H2flow at 888 635 0296 toll free or 1 419 841 7774 International TABLE OF CONTENTS Description front cover Concept front cover General Info Resources 2 Service Repair Kit 2 Models Compatibility Models 3 Compatibility 4 NSF 50 4 Chlorine Feeders 4 Safety Information Warnings Safety 5 Dimensions V...

Страница 3: ... Tee FV 4 4 80 GPM Complete FlowVis including Tee FV 4 L 4 80 LPM Complete FlowVis including Tee FV C Saline 2 40 GPM FlowVis for flotation tanks no check valve TABLE 2 METRIC DIMENSIONED MODELS MODEL PIPE SIZE PIPE SCHED SCALE DESCRIPTION FV C L DN50 65 DN50 65 40 LPM Complete FlowVis including valve body FV C L DN40 DN40 40 LPM Complete FlowVis including valve body FV L DN80 DN80 80 LPM Complete...

Страница 4: ...e or even chlorine gas into the surrounding filtration system When this occurs any equipment that comes into contact with these abnormal levels of chemicals will experience rapid and catastrophic damage Inspection of any failed components will quickly and conclusively confirm the cause of the damage and under these circumstances the product s warranty will be void Under no circumstances should Flo...

Страница 5: ...up anti entrapment system Such systems include but are not limited to SVRS and Automatic Pump Shut Off systems Special consideration must be made when installing a FlowVis to such applications Several of these systems do not allow the use of Check Valves It is the responsibility of the installer to make sure that the requirements of the specific backup system in use are maintained For these applic...

Страница 6: ...75 C Schedule 40 2 Slip 2 5 with coupling D 1 375 E 4 63 F 3 75 WEIGHT 1 5 lbs Models FV C FV C L FV C S FV C S L FV C Saline ENGLISH STANDARD ENGLISH STANDARD DIMENSION VALUE A 165 1 mm B 149 23 mm C Schedule 40 DN40 D 34 93 mm E 117 6 mm F 92 25 mm WEIGHT 0 544 kg Models FV C L DN40 METRIC DIMENSION VALUE A 165 1 mm B 149 23 mm C Schedule 40 DN50 Slip 65 with coupling D 34 93 mm E 117 6 mm F 92 ...

Страница 7: ... FV 3 L ENGLISH STANDARD DIMENSION VALUE A 203 2 mm B 241 3 mm C Schedule 80 DN80 D 47 63 mm E 114 3 mm F 107 96 mm WEIGHT 1 36 kg Models FV L DN80 METRIC DIMENSION VALUE A 9 5 B 9 75 C Schedule 80 4 D 2 25 E 5 25 F 5 0 WEIGHT 5 lbs Models FV 4 FV 4 L ENGLISH STANDARD DIMENSION VALUE A 241 3 mm B 247 65 mm C Schedule 80 DN100 D 57 15 mm E 133 26 mm F 127 0 mm WEIGHT 2 27 kg Models FV L DN100 METRI...

Страница 8: ...t require specific straight pipe lengths before or after its point of installation and can be installed close to or even adjacent to other plumbing fittings FlowVis can be installed either horizontally or vertically NOTE When selecting a physical location to install FlowVis be sure to allow accessibility to read the scale on the lid Pay particular attention to the system s direction of flow and ma...

Страница 9: ...t do not tighten at this stage 5 Using a hand Phillips head screwdriver slowly tighten the screws in a diagonal pattern per the sequence to the right Do not fully tighten one screw before proceeding to the next i e pull them down slowly multiple times to avoid stressing and cracking the lid Screws should be tightened to a final torque of 25 inch pounds or 34 Nm FLOW RANGE 9 1 2 3 5 4 6 7 8 Lid Ass...

Страница 10: ...2O 2 5 Schedule 40 Pipe 0 0 0 5 1 0 1 5 2 0 2 5 20 30 40 50 60 70 80 90 100 110 120 Head Loss psi FlowRate GPM FlowVis HeadLoss psi 2 Pipe 0 0 0 5 1 0 1 5 2 0 2 5 20 30 40 50 60 70 80 90 100 110 120 Head Loss psi FlowRate GPM Head Loss psi 2 5 Pipe 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 30 40 50 60 70 80 90 100 110 Head Loss Ft FlowRate GPM FlowVis HeadLoss ft H2O 2 Schedule 40 Pipe 0 0 0 2 0 4 0...

Страница 11: ...5 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 Head Loss Ft FlowRate GPM FlowVis HeadLoss ft H2O 4 Schedule 80 Pipe 0 0 0 1 0 1 0 2 0 2 0 3 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 Head Loss psi FlowRate GPM FlowVis HeadLoss psi 4 Schedule 80 Pipe Head Loss FV C Saline NOTE One 90 elbow equals 7 9 feet NOTE One 90 elbow equals 11 4 feet 0 0 0 1 0 1 0 2 0 2...

Страница 12: ...s important to position your eye so that you are looking squarely at the tip of the indicator arm To achieve this simply move your head so that you just lose sight of the vertical leading edge of the red arm Vertical leading edge NOTE Slowly move your head in this direction to the point where the leading edge of the indicating arm is not visible 1 2 3 1 Indicator arm is being viewed too far forwar...

Страница 13: ...d be made to the following Condition Check for Remedy Leak around lid seal O Ring Failure Replace O Ring Leak from lid Cracks in lid Order new lid from supplier Higher flow reading than normal Broken or weak spring Replace spring Lower flow reading than normal Indicator arm stuck due to debris Remove lid and clear debris Flow indicator stuck at one position Debris between indicator arm and lid Rem...

Страница 14: ...shings PVC Indicator Arm ABS Flapper 1 5 2 2 5 and DN40 DN50 65 PPEPS Flapper Seal 1 5 2 2 5 and DN40 DN50 65 Viton Flapper FV C S and FV C Saline only ABS Lower Flapper 3 DN80 and 4 DN100 only ABS Interconnecting link 3 DN80 and 4 DN100 only 316 Stainless Steel Lower Retaining Pins 3 DN80 and 4 DN100 only 316 Stainless Steel Materials used Function Models Comments Max working pressure All models ...

Страница 15: ...ther than H2flow Controls Inc staff to repair or service the product c damage has been caused by the improper use of the product including but not limited to the installation of a FlowVis unit using a chlorination system as described on page 4 of this manual 5 Charges Under cover of this warranty H2flow Controls Inc will pay the carriage and insurance charges for the shipment of defective product ...

Страница 16: ...45 Silica Road Unit F Sylvania OH 43560 U S A Tel 888 635 0296 Toll Free OR 1 419 841 7774 International Fax 419 517 9900 For international sales and service please visit our website www h2flow net Release 4 5 12 17 English Notes ...

Отзывы: