Technical data

Exhibition model:

Electrolyzer:

Fuel Cell:

Accessories:

H x W x D:
Weight:

H

2

 Production:

O

2

 Production:

Permissible current:
Permissible operating voltage:
Electrode area:
Guide value for distilled water:
Permitted operating pressure:
H x W x D:

Short circuit current:
Open circuit voltage: 
Power output:
Electrode area:
Permitted operating pressure:
H x W x D:

Water reservoir:
Solar module:
Load (fan):

700 x 300 x 1300 mm
4.8 kg

35 mL/min
17.5 mL/min
0 - 5 A
0 - 2.0 VDC
36 cm

2

<2 μS/cm
0 - 20 mbar
100 x 100 x 40 mm

3.3 A
1 VDC
1.2 W
16 cm

2

0 - 20 mbar
80 x 80 x 40 mm

approx. 500 mL / reservoir
2.0V / 1.0 A
10 mW

Содержание D201

Страница 1: ...Operating Instructions D201 Exhibition Kit...

Страница 2: ...s 03 03 03 04 06 07 08 11 12 14 15 15 15 The Exhibition Set About these instructions Safety information Contents Overview Starting up Operation Technical Data Troubleshooting Shutting Down Maintenance...

Страница 3: ...g instructions have to be read and observed before use These operating instructions have to be available for reference and have to be stored in a safe place All safety instructions must be observed Th...

Страница 4: ...4 www myhtec com Contents 1x Demonstration model 2x Overflow tanks 1x Solar module 1x Fuel cell gas flow indicator Water trap 1x Fan module...

Страница 5: ...www myhtec com 5 2x Cable Set 1x Companion text book Additional tools required 2 5mm hex key Connection cables 4mm 50cm length red Connection cables 4mm 50cm length black...

Страница 6: ...fuel cell via the water reservoir and a system of tubes where provided a load consumer is connected they are converted back to water while electrical energy and heat are being generated The demonstra...

Страница 7: ...torage and transportation is carried out in reverse order to assembly Do not yet connect the power supply to the electrolyzer Fig 3 Filling Distilled water 2 S cm Filling Fill the water reservoir with...

Страница 8: ...cations as defined in the technical data Provide the solar module with adequate direct sunlight or with light from a powerful concentrated electrical light source The shadow of an individual module cr...

Страница 9: ...e each use Risk of injury from hot surfaces A diode on the underside of the base plate protects the electrolyzer against reverse polarity The protection diode becomes very hot in case of incorrect pol...

Страница 10: ...when operating solar modules with lamps Risk of damage due to improper handling Operating the electrolyzer using water with an electrical conductivity of 2 S cm will cause irreparable damage to the e...

Страница 11: ...for distilled water Permitted operating pressure H x W x D Short circuit current Open circuit voltage Power output Electrode area Permitted operating pressure H x W x D Water reservoir Solar module L...

Страница 12: ...cell with a dry Polymer Electrolyte Membrane will lose power Water has entered the fuel cell during operation This can cause a rapid decline in performance Turn the overflow tanks clockwise until the...

Страница 13: ...H TEC EDUCATION Despite correct setup the electrolyzer or the fuel cell is not working The light intensity is insufficient The fan is broken The solar module is defective No distilled water was used T...

Страница 14: ...Emptying the water reservoir Disconnect the power supply from the connections on the electrolyser Any hydrogen present has to be consumed before draining the storage tanks To extend the water outlets...

Страница 15: ...operation remove the water from the water reservoir In the original packaging At temperatures from 4 C to 50 C Protected from shock and vibrations According to European regulations used electric and e...