h/p/cosmos motion stair 600 Скачать руководство пользователя страница 4

 

User manual motion stair 600

 med/600 

Version 3.0 

Page 

4

 of 

19

 

 

 

Place  the  unit  on  a  solid,  flat  and  non-sliding  ground  and  level  the  unit  with 
the adjusting feet, so that it does not move. 

 

For the set-up a safety clearance of 100 cm to all sides is necessary to ensure a 
safe  access  also  in  emergencies.  Safety  clearances  between  the  devices  are 
allowed to overlap; see picture.  

 

The usage may only take place in dry rooms (< 65% humidity, > 0 < 45°C room 
temperature). 

 

Pay attention that there is no electromagnetic radiation like mobile phones  or 
fluorescent tubes, because they may affect the measurement of the heart rate.  

 

Do not locate the units on thick rubber mats. Ensure that the unit gets airing from all sides. 

 

All units of the cardio line are self-powered. The user will either generate the electricity by pedalling or 
– especially while programming  – will be supported by the standard, built-in battery pack. The battery 
power will last for about two years. See topic “5 Maintenance” for battery change.

 

 

Attention:

 Please consider the standards for care, maintenance and servicing in chapter 5 of this manual. 

 

3.2

 

Safe training 

 

Before  starting  to  exercise,  the  fitness  of  the  user  has  to  be  ensured  by  an  authorised  specialist  or  a 
doctor. Please note topic 3.3 Indications and Contraindications.  

 

Excessive exercise can be dangerous. 

 

When nausea or dizziness occurs, the work-out has to be stopped right away and a doctor needs to be 
allocated.  

 

The training on the units is allowed with unbruised skin only. 

 

While  exercising  light,  tight  fitting  clothing,  which  cannot  be  caught  in  parts  of  the  unit  is 
recommended. Always wear sports shoes to ensure a good balance on the pedals. 

 

Please check the unit before exercising for a good level, faulty parts or other manipulations. In case of a 
defect or if you are not sure, ask a supervisor.   

 

Before the start of the workout it must be assured that no one is close to moving parts, to avoid danger 
for a third person. Above all, hold unattended children off the units. 

 

As  a  safety  function,  the  stop  button  is  always  active  and  immediately  slows  down  the  motion  when 
pushed. 

 

Warning: 

Both  pedals  will  be  backtracked  to  their  initial  position  by  a  tension  spring.  To  prevent  the 

customer from injuries we recommend to step on and train like described below:

 

1.

 

Stand in front of the machine an hold on the handle bars 

2.

 

Step on one pedal with one foot and push down the first pedal 

3.

 

Shift your weight to the  side of the pushed down pedal 

4.

 

Push down the second pedal with your other foot 

5.

 

Both pedals are pushed down 

6.

 

Start pedalling by making step climbing movements. Do not bump on both end positions. 

7.

 

If  you  want  to  stop  training  just  stop  pedalling.  Both  pedals  will  slide  downwards  until  they 

touch the floor. 

8.

 

Now, let one pedal rise to the upright end position. 

9.

 

When the pedal is in the upper position you can step off with the first foot. Afterwards let the 

second pedal rise into the upright position. 

10.

 

Step off with the second foot. 

11.

 

Please practise to step on and off this machine for a safe training 

 

The  training  with  the  motion  stair  600  is  a  coordinative  demanding  movement.  Additionally  this 

machine can cause a strenuous endurance training. The sinking speed is influenced by the machines level 
and the user weight. 

 

Warning: 

The  system  to  control  the  heart  rate  can  be  faulty.  Excessive  workouts  can  lead  to  serious 

injury or death. When nausea or dizziness occurs, the work-out has to be stopped right away.

 

 

Warning:

 Solely use unit with the casing. 

 

 

Warning  if  using  optional  power  supply:

  Use  exclusively  medical  power  supply  units  according  to  IEC 

60601-1 which are approved by the manufacturer.

 

/H-p-cosmos.local/dfs/erp$/article/cos30021ef-med600/manual/EN/20170926_cos30033ef-med600-ef-600_torqualizer_stair_instructions_for_use_EN.pdf

Содержание motion stair 600

Страница 1: ...00 Version 3 0 Page 1 of 19 User manual for the motion stair 600 med and the motion stair 600 H p cosmos local dfs erp article cos30021ef med600 manual EN 20170926_cos30033ef med600 ef 600_torqualizer...

Страница 2: ...12 Programs of the cardio line 10 4 13 Pulse controlled programs 15 4 14 PC Interface 15 5 Maintenance 16 5 1 Instructions for the error condition detection failure 16 5 2 Instructions for preventive...

Страница 3: ...tandard DIN EN ISO 20957 1 and DIN EN ISO 20957 5 usage class S commercial use gyms of the accuracy class A 10 and designed to suit the needs of fitness gyms and preventive fitness The items of the ca...

Страница 4: ...e not sure ask a supervisor Before the start of the workout it must be assured that no one is close to moving parts to avoid danger for a third person Above all hold unattended children off the units...

Страница 5: ...y can be equipped with a Polar hand pulse system combined with a coded wireless signal transmitter With this technology two advanced measuring systems work together The hand pulse measurement has prio...

Страница 6: ...a if the workout has been started using a storage media The Scan button changes the display mode parameters or graphical displays within the Dot Matrix on the monitor The Smart Key buttons function as...

Страница 7: ...alories burned or the remaining calories to be burned are shown Level Display of the actual intensity 1 21 Storage media The symbol for the storage media appears whenever a member card is inserted int...

Страница 8: ...the handling of the unit The storage media system supports the user in all aspects of training activities The system consists of a monitor unit with the storage media reader The slot used to enter th...

Страница 9: ...r four seconds each After that the personal workout that was previously saved on the storage media is being started automatically and the workout session can begin The storage media can be removed aft...

Страница 10: ...x x x x 5 Isokinetik 6 Therapy x x x X 7 Interval x x 8 K cal x x x x 9 Hill x x x 10 Random x 11 Distance x x x Tab 1 Programs of the cardio line med separated by units usage and biofeedback program...

Страница 11: ...le By doing so the user can perform a so called cross training whereby the resistance is adjusted to the expected wattage during the workout and the ergometer will simply make fine tunings to the resi...

Страница 12: ...cates the hill profile remaining and the actual position during the workout The intensity will be shown permanently as level or as wattage speed The heart frequency is shown if the trainee is using on...

Страница 13: ...this symbol you start and end the programming of an interval sequence Stepless load increase through the time of the sequence Increasing by steps Finish of the interval programming symbol request of s...

Страница 14: ...doesn t get used by an individual In this case you can ignore the results The display shows writing Program for some seconds The program is now stored on the media The storage media can now be used A...

Страница 15: ...e as well as intensity alongside the recovery progress As a general rule intensity changes occur by increasing the workload e g increasing of the wattage At the therapy training the intensity gets var...

Страница 16: ...for damages and tightness In general Clean the devices with mild purifier and a wet cloth to get off aggressive sweat Dry the device afterwards The usage of spray bottles is not allowed it has shown...

Страница 17: ...ed control According to the transposition of the medical device directive 93 42 EEC into national law At elliptical and stairclimbing machines cross and stair Metrological Controls are not required by...

Страница 18: ...cedures are possible 1 The service is conducted on site by our service employees 2 The required spare part s are shipped 3 An exchange unit is arranged and sent to the user The defective parts must be...

Страница 19: ...ness GmbH Co KG Trippstadter Str 68 67691 Hochspeyer Germany Tel 49 0 6305 71499 0 Fax 49 0 6305 71499 111 info emotion fitness de www emotion fitness de H p cosmos local dfs erp article cos30021ef me...

Отзывы: