Solenoid Pump Instructions

body.

Unscrew the diaphragm from the pump 
shaft in a counter-clockwise direction. Be 
careful that diaphragm support ring does 
not fall out.

Do not allow sharp or abrasive objects to 
come in contact with pump parts.

Inspect end of shaft to assure that threads
are in good condition. Replace shaft 
bellows if necessary. No further 
disassembly is recommended.

Screw new diaphragm onto pump shaft 
until it bottoms out on shoulder of shaft. It 
is not necessary to tighten further.

Replace liquid end. Make sure that 
screws are evenly tightened.

Reconnect plumbing and power. Prime 
the pump.

Servicing the Chemical Valves

CAUTION!  If the suction line 
exits your chemical tank through
a bulkhead fitting the tank 
should be empty before 
servicing the chemical fittings.

WARNING! Chemical fittings and
tubing contain chemicals. 
Spillage and leakage will occur 
when disconnecting fittings. 
OBSERVE PROPER 
PRECAUTIONS FOR THE 

CHEMICALS BEING PUMPED!

If you have an Anderson injection point fitting 
(Illustration 1) you may service the suction and 
discharge check valves and Foot Valve/Bulkhead/ 
Flush Fitting, with the system under pressure, but 
you should turn off the water flow through the 
feeder.

To service the injection point fitting, or if there is a 
failure of an injection point fitting, you must 
remove pressure from the system (shut off the 
water upstream of the unit).

Refer to the specific manual for servicing H.E. 
Anderson IPFs available at 

http://www.heanderson.com/manuals.php

.

Replacing Suction and Discharge
Valves

Unplug the pump and ensure it is 
disconnected from power.

Disconnect suction tubing from pump.

Unscrew fitting from pump head.

Remove check valve from suction fitting 
and replace.

Remove O-ring from cavity in fluid end.

Remove check valve from suction side 
pump and replace.

Install new O-ring in cavity of fluid end.

Replace valve fitting with check valve in 
fluid end.

Replace fluid end. Make sure that screws 
are evenly tightened.

Reconnect plumbing and power. Prime 
the pump.

Notes: 

Tighten pump head screws after pump’s 
initial week of operation.

Solenoid Pump 10-2017

7

H.E. Anderson Co.

Содержание SP-15M-VCP

Страница 1: ...o contact us via e mail at info heanderson com Before you call review this manual You may find the answer to your question here But if not reviewing the manual will help us to help you If you need an...

Страница 2: ...the flow meter and tee s for the injection point fitting s should be completed before installing the pumper s See the Installation Guidelines and Operation of Ratio Feeder Series J Plus Injectors for...

Страница 3: ...rp bends that might collapse into a kink Once a proper length piece of tube has been cut place a tube nut onto each end of the tube making sure the threads of the nut face the adapters Press the tube...

Страница 4: ...to the controller and pump before making any electrical connections Solenoid pumps require 120VAC 60hz 0 6 amps 0 066kw Do not remove the grounding terminal on the plug Model P with J Advanced Contro...

Страница 5: ...ould be repeated for each pump if multiple pumps are installed If the pump will not prime properly check all the tubing connections for tight connections and repeat the priming process If prime still...

Страница 6: ...zing temperatures Our warranty does not cover freeze damage Problems With Chemicals Some chemicals may not be compatible with the pumper diaphragm You should check compatibility of a chemical with the...

Страница 7: ...If you have an Anderson injection point fitting Illustration 1 you may service the suction and discharge check valves and Foot Valve Bulkhead Flush Fitting with the system under pressure but you shoul...

Страница 8: ...uctions Other replacement and repair parts 04094 IPF 1 2 Universal Complete 06892 Tubing Bulk 3 8 OD Black for acid 06909 Tubing Bulk 3 8 OD Clear 17087 Suction Pipe 2 piece x 33 H E Anderson Co 8 Sol...

Страница 9: ...Solenoid Pump Instructions Specifications Solenoid Pump 10 2017 9 H E Anderson Co...

Отзывы: