Solenoid Pump Instructions
body.
●
Unscrew the diaphragm from the pump
shaft in a counter-clockwise direction. Be
careful that diaphragm support ring does
not fall out.
●
Do not allow sharp or abrasive objects to
come in contact with pump parts.
●
Inspect end of shaft to assure that threads
are in good condition. Replace shaft
bellows if necessary. No further
disassembly is recommended.
●
Screw new diaphragm onto pump shaft
until it bottoms out on shoulder of shaft. It
is not necessary to tighten further.
●
Replace liquid end. Make sure that
screws are evenly tightened.
●
Reconnect plumbing and power. Prime
the pump.
Servicing the Chemical Valves
CAUTION! If the suction line
exits your chemical tank through
a bulkhead fitting the tank
should be empty before
servicing the chemical fittings.
WARNING! Chemical fittings and
tubing contain chemicals.
Spillage and leakage will occur
when disconnecting fittings.
OBSERVE PROPER
PRECAUTIONS FOR THE
CHEMICALS BEING PUMPED!
If you have an Anderson injection point fitting
(Illustration 1) you may service the suction and
discharge check valves and Foot Valve/Bulkhead/
Flush Fitting, with the system under pressure, but
you should turn off the water flow through the
feeder.
To service the injection point fitting, or if there is a
failure of an injection point fitting, you must
remove pressure from the system (shut off the
water upstream of the unit).
Refer to the specific manual for servicing H.E.
Anderson IPFs available at
http://www.heanderson.com/manuals.php
Replacing Suction and Discharge
Valves
●
Unplug the pump and ensure it is
disconnected from power.
●
Disconnect suction tubing from pump.
●
Unscrew fitting from pump head.
●
Remove check valve from suction fitting
and replace.
●
Remove O-ring from cavity in fluid end.
●
Remove check valve from suction side
pump and replace.
●
Install new O-ring in cavity of fluid end.
●
Replace valve fitting with check valve in
fluid end.
●
Replace fluid end. Make sure that screws
are evenly tightened.
●
Reconnect plumbing and power. Prime
the pump.
Notes:
●
Tighten pump head screws after pump’s
initial week of operation.
Solenoid Pump 10-2017
7
H.E. Anderson Co.