Solenoid Pump Instructions

Now insert the solenoid pump wires into the water
meter terminal block. 2 wires will share 1 
connection position. The black wire connects to 
the #1 connection and the red wire connects to 
the #2 connection. Tighten the connections and 
ensure that both the water meter wires and the 
solenoid pump wires are not loose.
After the pump has been properly wired to the 
controller, plug the pump into the power outlet and
proceed to priming section.

Priming

Place the foot valve/strainer into a container of the
solution to be pumped, again following all 
applicable safety procedures for the chemical 
being pumped.

The priming valve located on the back of the 
pump should be opened to assist with priming the 
pump. If the pump is equipped with a universal or 
priming IPF, the priming valve on the IPF can be 
used instead of the valve on the pump. 

Ensure that the stroke capacity knob on the pump 
is set to 100%.

Be careful to only adjust the stroke 
capacity knob when the pump is pumping.
Damage will occur if the knob is adjusted 

while the pump is off.

Prime the pump by using the ‘Prime’ feature on 
the J+ Advanced controller. See the J+ Advanced 
manual for instructions. Continue the priming 
routine until solution can be seen flowing from the 
priming valve. Once solutions starts to run out the 
vent of the priming valve, close the priming valve 
and cease priming the pump. 

These instructions should be repeated for each 
pump if multiple pumps are installed.

If the pump will not prime properly, check all the 
tubing connections for tight connections and 
repeat the priming process. If prime still cannot be
achieved, consult factory support.

WARNING! 

When working with

hazardous chemicals use 
extreme caution and carefully 
follow the handling instructions 
and safety procedures in the 
Material Safety Data Sheets. Use 
only the 04094 Universal IPF 
when feeding acid.

START-UP

Place the foot valve/strainer into the filled 
solution tank.

If installing it as a bulkhead fitting, install it
about 2 inches above the bottom of the 
tank, to prevent the strainer from 
becoming fouled by sediment which may 
collect on the bottom.

Set the pumpers to the number on the dial
calculated to give the desired feed. Fill 
your concentrate tanks and restart your 
feeder. It should now be operational. You 
may need to check, as done in the initial 
check-out, to be sure the pumpers are 
properly primed.

Make sure the pump controller is properly 
configured by referring to the controller 
specific manual.

Turn on flow to begin operation.

MAINTENANCE

Normally the pump should require little 
maintenance. This, however, depends on the 
quality and cleanliness of the chemical being 
pumped.

Before any maintenance or service is performed, 
observe the following precautions:

Disconnect the Solenoid Pump from 
power source.

Drain chemical from discharge tubing.

Disconnect discharge tubing from pump.

If the Solenoid Pump is used in a flooded 

Solenoid Pump 10-2017

5

H.E. Anderson Co.

Do not connect SP here

Water Meter Wire

Solenoid Pump Wire

Содержание SP-15M-VCP

Страница 1: ...o contact us via e mail at info heanderson com Before you call review this manual You may find the answer to your question here But if not reviewing the manual will help us to help you If you need an...

Страница 2: ...the flow meter and tee s for the injection point fitting s should be completed before installing the pumper s See the Installation Guidelines and Operation of Ratio Feeder Series J Plus Injectors for...

Страница 3: ...rp bends that might collapse into a kink Once a proper length piece of tube has been cut place a tube nut onto each end of the tube making sure the threads of the nut face the adapters Press the tube...

Страница 4: ...to the controller and pump before making any electrical connections Solenoid pumps require 120VAC 60hz 0 6 amps 0 066kw Do not remove the grounding terminal on the plug Model P with J Advanced Contro...

Страница 5: ...ould be repeated for each pump if multiple pumps are installed If the pump will not prime properly check all the tubing connections for tight connections and repeat the priming process If prime still...

Страница 6: ...zing temperatures Our warranty does not cover freeze damage Problems With Chemicals Some chemicals may not be compatible with the pumper diaphragm You should check compatibility of a chemical with the...

Страница 7: ...If you have an Anderson injection point fitting Illustration 1 you may service the suction and discharge check valves and Foot Valve Bulkhead Flush Fitting with the system under pressure but you shoul...

Страница 8: ...uctions Other replacement and repair parts 04094 IPF 1 2 Universal Complete 06892 Tubing Bulk 3 8 OD Black for acid 06909 Tubing Bulk 3 8 OD Clear 17087 Suction Pipe 2 piece x 33 H E Anderson Co 8 Sol...

Страница 9: ...Solenoid Pump Instructions Specifications Solenoid Pump 10 2017 9 H E Anderson Co...

Отзывы: