28
SAM-1A
EN
APPENDIX 1 - SAM-1A SETTINGS USING THE NEOPULSE/PULSEMIG
1.
NEOPULSE/PULSEMIG digital inputs/outputs
.....................................................................................................
28
a)
Digital inputs
.....................................................................................................................................................................28
b)
Digital outputs
...................................................................................................................................................................28
2.
NEOPULSE/PULSEMIG analogue inputs/outputs
...............................................................................................
28
a)
Analogue outputs
...............................................................................................................................................................28
b)
Analogue input functions
....................................................................................................................................................29
I.
JOB mode - Without settings
........................................................................................................................................29
II.
JOB mode - Current settings
........................................................................................................................................29
III.
JOB mode - Wire-speed settings
...................................................................................................................................30
IV.
Manual Mode
..............................................................................................................................................................30
3.
Where to find the JOB number
....................................................................................................................................
31
4.
Where to find the synergy values
..............................................................................................................................
31
5.
How to change the management mode to find the min./max. setting values
......................................
31
1.
Digital inputs/outputs for NEOPULSE/PULSEMIG machines
a)
Digital inputs
The SAM-1A has four digital inputs as detailed below:
Status
Pin
Connector
0
1
MMI_LOCK
X20-18
Current-Voltage multimeter mode
Accessing the power source settings
Start_Process
X20-19
Stopping the welding process
Starting the welding cycle
Start_Gaz
X20-20
GAS solenoid valve closed
GAS solenoid valve open
Wire_Feed
(only in MIG)
X20-16
Wire stopped
Unwinding the wire
b)
Digital outputs
As well as the following four digital outputs:
Status
Pin
Connector
0
1
Error
X20-6
No error
Error detected
Authorised_Start
X20-7
Welding prohibited
Welding permitted
Arc_Detect
X20-14
Arc not detected
Arc detected
Welding_Process
X20-8
No welding in progress
Welding in progress
Main_Current
X20-13
Outside the main welding phase
In the main welding phase
2.
NEOPULSE/PULSEMIG analogue inputs/outputs
a)
Analogue outputs
The
SAM-1A
has
two
analogue
outputs
providing
voltage-
and
current-measurement
information
as follows:
Voltage measurement (M_Weld_Voltage, X20-5): varies from 0 - 10 V and covers a measurement range of 0 - 50 V.
Current measurement (M_Weld_Current, X20-15): varies from 0 - 10 V and covers a measurement range of 0 - 500 A.