19
STARTIUM 330E / 480E / 680E / 980E
EN
Translation of the original instructions
TROUBLESHOOTING
Symptoms
Causes
Remedies
The error LED switches on
Power supply problem.
Check your mains power supply.
The error LED switches on and the buzzer
Clamps in short circuit or polarity inversion.
Check that the fuses have not melted.
Do not put the clamps in short circuit. Reverse
polarities.
The battery that you are trying to charge is
faulty.
Check the terminals’ voltage with a voltmeter.
If this voltage jumps instantaneously to 2.5V
per element, the battery may be sulfated or
damaged.
Voltage error (12 -24 V)
Check that the clamps are properly connected
in 12V or 24V.
Battery not connected or <1V. Display: «BAt
HS»
Connect a battery.
Select TIMER if the battery voltage is <1V.
Following intensive use, your device has ente-
red thermal protection mode. Display : «th»
Wait 1/4h so the device can cool down.
Desulphation charging time > 1h
The battery cannot be recovered.
Change the battery.
No LED switches on
Major power supply fault
Check your mains power supply.
Machine overheat, the thermal protection «th»
activates.
Ventilate the area.
The start/stop button is not pressed.
Press the start/stop button.
In START ENGINE mode, the display shows
0%. The start is impossible.
The batterty is sulfated, the machine will
automatically block the start in order to protect
on-board electronics.
Charge the battery before re attempting a
START ENGINE.
The battery boils.
The voltage selection 12V or 24V is incorrect.
Charge the battery before re attempting a
START ENGINE.
Your battery has elements in short circuit.
The battery cannot be recovered, it must be
changed.
Sparks at the clamps
Polarity reversal
Connect the clamps the correct way (+/+;-/-)
Timer mode active
Cf. Connection and disconnection
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
Содержание STARTIUM 330E
Страница 63: ......
Страница 64: ...GYS SAS 1 rue de la Croix des Landes CS 54159 53941 SAINT BERTHEVIN Cedex France ...