18
GYSFLASH 40-12 FV
EN
Shortcut to Lock Showroom :
The «Lock Showroom» feature can be activated without accessing the configuration menu.
• Turn OFF the device (main switch in the OFF position)
• Press MODE key
MODE
• Turn ON the switch, while the MODE key is still pressed. The screen displays «GYSFLASH 40-
12 FV Vx.x» for 3 seconds.
• Hold the MODE key until the creen displays «lock showroom: Y»
• Cables calibration :
This mode must be used each time the cables are changed. The GYSFLASH can be fitted with cables up to
2x8m in 16mm².
OK : The calibration was successful.
FAIL : A problem occurred during the calibration. In this case, the calibration is reset to the factory setting.
Check that the cables are in good condition and properly put in short-circuit and repeat the procedure.
• ADVANCED MENU (code 1-9-6-4) :
This menu is intented for experimented user only.
To access this menu, enter in the code above («Select» key to change the digit selection and «Start/Stop» key to
confirm the code).
For more details, see page 19.
• Reset Memory (code 1-9-6-4) :
This menu is intented to factory reset the charger
settings by entering the code above. Any personal
parameters are deleted.
RESET MEMORY
RESET MEMORY
Code OK
Yes
No
RESET MEMORY
Reset all ?
RESET MEMORY
Code:
0000
Code OK
(1964)
RESET MEMORY
Error Code
Code NOK
Display 1s
0
1
...
9
Change the
code number