23
GYSFLASH 101.12 CNT / 121.12 CNT FV /
123.12 CNT FV / 103.24 CNT FV
EN
2
Confirm the recording of the charging data.
Continue?
Yes
3
The charger will then copy the charging data to the USB stick as files, « .CSV »
Loading
Custom configuration
List of modes and profiles available for customization:
CHARGE MODE
Charge
type:
Charge
profiles
Charging voltage
Pb-CHARGE
normal
2.40 V/cell
Charging profile for lead batteries of the types Gel, MF, EFB, SLA...
AGM
2.45 V/cell
Charging profile for most AGM lead-acid batteries including START and STOP.
However, some AGM batteries require a lower voltage charge (Normal profile). Check the
battery manual if in doubt.
water
2.45 V/cell
Charging profile for open liquid-type lead-acid batteries with plug.
Easy
2.40 V/cell
Charging profile dedicated to lead batteries that automatically adapts the charging current
according to the size of the battery.
However, for maximum charge optimization, it is recommended, when possible, to use
normal, AGM or liquid charge curves.
boost
2.42 V/cell
Maximum current charge for lead-acid battery. This type of charge is ultra-fast.
Warning : this type of charge must remain occasional in order to preserve bat-
tery life.
r
2.40 - 2.50 V/cell
Charging profile for the recovery of severely damaged lead batteries. It is essential to
recover the battery outside the vehicle to avoid damaging the vehicle electronics and in a
well ventilated area.
Caution: Recovery voltage up to 4.0 V/cell.
Li-CHARGE
LFP/LiFePO4
3.60 V/cell
Charging profile for Lithium batteries type LFP (Lithium Ferro Phosphate)
Li-ion std
4.20 V/cell
Charging profile for standard lithium-ion batteries based on Manganese or Cobalt (NMC,
LCO, LMO, MCO...)
LFP cell+
3.60 V/cell
Charging profile dedicated to LFP (Lithium Ferro Phosphate) type lithium-ion cells with
selection of the number of cells in series to be charged.
Li-ion cell+
4.20 V/cell
Charging profile dedicated to standard lithium-ion cells based on Manganese or Cobalt
(NMC, LCO, LMO, MCO...) with selection of the number of cells in series to be charged.
TRACTION
water
2.42 V/cell
Charging profile dedicated to open lead traction batteries for forklift trucks.
gel
2.35 V/cell
Charging profile dedicated to gel-type traction batteries for forklift trucks.
POWER MODES
Showroom
Maintains the battery's state of charge and supplies power when using the electrical consumers of a demonstra-
tion vehicle.
DIAG+
Supplies energy requirements during the vehicle diagnostic work.
CHANGE BAT.
Allows to keep the vehicle power supply during battery replacement, in order to preserve the memory of the
vehicle's ECUs.
Caution: Reverse polarity during use can be harmful to the charger and vehicle electronics.
POWER SUPPLY
Allows the charger to be used as an adjustable stabilized power supply with high power. The voltage to be regula
-
ted and the current limitation are fully adjustable.
Caution: Reverse polarity during use can be harmful to the charger and vehicle electronics.
Li-SUPPLY/LFP
Mode intended to supply lithium-ion cells of the LFP type (Lithium Ferro Phosphate) with selection of the number
of cells in series, adjustment of the voltage and current to be applied.
Li-SUPPLY/Li-ion
Mode intended to supply standard lithium-ion batteries based on Manganese or Cobalt (NMC, LCO, LMO, MCO...)
with selection of the number of cells in series, adjustment of the voltage and current to be applied.
MISCELLANEOUS
TESTER MODE
Allows to check the state of the battery, to evaluate the starting of the vehicle as well as the operation of the
alternator