POWERDUCTION 37LG / 39LG / 50LG
EN
Translation of the original instructions
• Keep the head away from the fumes, do not inhale.
• If working inside, ventilate the area or use a fume extractor to eva-
cuate the gases and fumes.
• Induction heating of certain materials such as adhesives and flux
can generate fumes and gases. Breathing these fumes and gases
can be dangerous for your health. For example, heating urethane
generates a gas : hydrogen cyanide, potentially mortal for humans.
• If the ventilation is insufficent, use an approved respiratory unit.
• Read the safety data sheets (MSDS) and the manufacturer’s instruc-
tions for adhesvies, flux, metals, consumables, coatings, cleaning
agents, corrosives, and paint strippers.
• Do not use the heater on parts being degreased or sprayed. The
heat might react with fumes and generate highly toxic gases.
• Work in a confined area only if it’s well ventilated, or use an appro-
ved repiratory/filtration unit. Make sure that a qualified person is
around to watch over you. The fumes and gases released while
heating can replace oxygen or air, causing accidents or death.
Check the quality of the air you’re breathing
• Do not overheat metals, such as galvanised steel, covered with lead
or cadmium, unless the coating is removed from the surface before
it’s heated, that the area is well ventilated, and if needed, use an
approved filtration/respiratory unit.. Foundry pieces and all metals
containing such elements may generates toxic fumes if overheated.
• Check the MSDS for temperature related details.
Warning, electrical danger
Warning ! Major magnetic field. People wearing active or
passive implants must be informed.
No further protectective steps are required when the machine is used
on its own. Further restrictions and/or protective measures may be
necessary in other cases.
After maintenance, the magnetic field levels must be checked before
the machine is used again.
When switched on, never put the inductor near the head or vital or-
gans.
Caution: Danger of optical radiation when the heated metal ele-
ments reach fusion.
People wearing pacemakers are advised to not come close to the
machine. Risk of disruption of pacemaker operations when close to
the machine.
Consult a doctor before getting close to induction heaters.
Risk of metal or adhesive projections
• Wear approved protective goggles with lateral protections, or
protect the whole face with a screen.
• Wear protective clothes.
• Wear gloves.
Содержание 055599
Страница 7: ...POWERDUCTION 37LG 39LG 50LG 7 2 vis M5x16 41072 2 vis M8x40 42066 ...
Страница 8: ...8 POWERDUCTION 37LG 39LG 50LG 39LG 2 vis M8x40 42066 2 vis M5x10 41025 6 vis M6x16 41032 ...
Страница 9: ...POWERDUCTION 37LG 39LG 50LG 9 37LG si option chariot if trolley option ...
Страница 13: ...POWERDUCTION 37LG 39LG 50LG 13 I 50LG 39LG 37LG 3 4 5 6 7 8 9 10 11 12 13 14 17 11 12 16 15 2 1 2 1 2 1 ...
Страница 99: ......
Страница 100: ...SAS GYS 1 rue de la Croix des Landes CS 54159 53941 SAINT BERTHEVIN Cedex ...