background image

 

 

Sample   Wiring   Diagrams 

These   wiring   diagrams   are   intended   only   as   examples   of   how   the   relay   unit   and   RFID   device   may 
be   installed.   Actual   installation   wiring   may   differ.  

The   difference   between   fail   secure   and   fail   safe   electronic   locks   are   as   follows:  

● Fail   secure   locks   will   lock   the   door   when   the   power   goes   off,   whereas 
● Fail   safe   locks   will   leave   the   door   unlocked   when   the   power   goes   off. 

 

Fail-Secure 

 

 

 

 

 

EPIC   Sanctuary 
78­106   Manchester   St 
Christchurch   8011 
New   Zealand 

PO   Box   13352 
Armagh   Mail   Centre 
Christchurch   8011 
New   Zealand 

www.gymmastersoftware.com 

NZ   03   974   9169 
AU   03   9111   0323 
US   415   678   1270

 

Page   6 

 

Содержание Gatekeeper h4.0

Страница 1: ...iring Instructions Gatekeeper h4 0 Technical Support support gymmastersoftware com USA 415 678 1270 Australia 03 9111 0323 New Zealand 03 974 9169 Copyright 2016 Treshna Enterprises All rights reserve...

Страница 2: ...ly Open Contacts Normally Closed Contacts Gatekeeper Status What do the lights mean Troubleshooting Gatekeeper s Power Button is not turning on Gatekeeper s Ser1 Ser2 light s are not turning on Door R...

Страница 3: ...may be supplied with Desktop card reader regular USB data cable Wall mounted card reader with Diode You will also need the following items Battery and power supply Router or network switch Internet co...

Страница 4: ...atekeeper and Card Reader to optimize the full benefits of the Gatekeeper as well as for security in the event of power failure It is necessary that an Emergency Fire Exit Button be included in your d...

Страница 5: ...are often inductive switching off the current can cause a voltage spike on the wires to the access control damaging the reader A snubber should be fitted near any switch or relay contacts for DC circ...

Страница 6: ...Screw Terminals Some readers have screw terminals instead of wires Use the following key to interpret the diagrams All other terminals are not used Terminal Wire Colour VCC Red GND Black A Green B Whi...

Страница 7: ...and fail safe electronic locks are as follows Fail secure locks will lock the door when the power goes off whereas Fail safe locks will leave the door unlocked when the power goes off Fail Secure EPIC...

Страница 8: ...rgency Exit EPIC Sanctuary 78 106 Manchester St Christchurch 8011 New Zealand PO Box 13352 Armagh Mail Centre Christchurch 8011 New Zealand www gymmastersoftware com NZ 03 974 9169 AU 03 9111 0323 US...

Страница 9: ...EPIC Sanctuary 78 106 Manchester St Christchurch 8011 New Zealand PO Box 13352 Armagh Mail Centre Christchurch 8011 New Zealand www gymmastersoftware com NZ 03 974 9169 AU 03 9111 0323 US 415 678 127...

Страница 10: ...gency Exit EPIC Sanctuary 78 106 Manchester St Christchurch 8011 New Zealand PO Box 13352 Armagh Mail Centre Christchurch 8011 New Zealand www gymmastersoftware com NZ 03 974 9169 AU 03 9111 0323 US 4...

Страница 11: ...haring wiring pattern above The wiring pattern you should use depends on which relay contacts are being used Normally Open Contacts In arrangements where the normally open NO contacts are used wire th...

Страница 12: ...er to the Gatekeeper unit 4 Error Red Off There is an error 5 Reader 1 Reader 2 On Off Reader s are connected 6 Database On Off Connection to the cloud server 7 Internet On Off Internet Connection 8 A...

Страница 13: ...es an electrical fault It could be 1 A wiring fault short circuit somewhere on the card reader cable 2 Something on the card reader cable is consuming too much power 3 a bad power supply 4 a faulty Ga...

Страница 14: ...from green to red If this does not happen then it would be due to the following causes Faulty tag Faulty reader Faulty cable Door has been disconnected from the Gatekeeper Tag has not been activated i...

Страница 15: ...ix Incorrect wiring to door lock or relay Faulty relay Note on Power Supply The power supply must provide 12V DC It is recommended that an uninterruptible power supply UPS is used to back it up EPIC S...