GPE-1326/2323/3323/4323 Series User Manual
38
CH1/CH2 Series Tracking Mode
Background
Series tracking operation allows the GPE-
2323/3323/4323 to combine the output by
internally connecting CH1 (Master) and CH2
(Slave) in series. CH1 (Master) controls the
combined output voltage/current level which is
set independently.
The following describes two types of
configurations, depending on how common
ground is used.
Series Tracking without Common Terminal
Connection
LO AD
GPE-4323
GPE-3323
GPE-2323
GPE-1326
Output rating
0 ~ 64V/0 ~ 3A
1.
Press the Series/Parallel key
to activate the series
tracking mode. The
SER
icon
will be lit on the LCD
display.
GPE-3323
www.
.com