SETTING THE TIME AND DAY OF THE WEEK

With the thermostat on, press the symbol        and the hour digits will flash. 

Use the      /      symbols to set the time. Press the symbol       again to move to 

the minutes and use the     /      symbols to set the minutes. Press the symbol 

again and the day of the week will flash. Use the      /       symbols to define the 

day of the week. Press the symbol      to complete the configuration.

SET TEMPERATURE IN MANUAL MODE

With the thermostat turned on in manual mode, press the symbol      to 

increase the temperature by 0.5ºC. Press the symbol        to lower the tempera-

ture by 0.5ºC.
The thermostat turns on when the probe temperature is lower than the one 

set at 1.5ºC and the symbol       appears on the display. The thermostat 

switches off when the probe temperature is higher than the one set at 1ºC.

VII - ADVANCED SETTINGS

SEN - PROBE SELECTION

In this function you can configure the probe to be used. Use the     /     symbols 

to set a value that can range from 0 to 2. Value 0 defines the exclusive use of 

the ambient probe (internal probe). The value 1 defines the exclusive use of 

the floor probe (internal probe). The value 2 defines the use of both probes 

(the ambient probe controls the temperature and the floor probe limits the 

temperature). The factory-set value is 0.
If option 2 is set (both probes in use), the thermostat screen in normal 

operation displays the temperature of the ambient probe. You can check the 

temperature of the floor probe by holding down the symbol         and pressing 

the symbol        at the same time.

OSV - FLOOR PROBE TEMPERATURE LIMIT 

This function allows you to configure the temperature limit of the floor probe. 

This value defines a safety temperature, from which or thermostat switches 

off, regardless of its programming. This setting only takes effect if used as two 

probes (option 2 of the probe selection - SEN). Use the        /       symbols to set 

the value that can range from 5ºC to 99ºC. The factory set value is 42ºC.

DIF - TEMPERATURE DIFFERENTIAL ASSOCIATED WITH THE THRESHOLD OF

THE FLOOR PROBE

In this function you can configure the temperature differential associated with 

the limit of the floor probe. For example, if you have set a value of 2ºC in this 

option, and if you have set 40ºC in the previous function, the thermostat will 

switch off at 42ºC and switch on again at 38ºC. Use the       /       symbols to

set the value that can go from 1ºC to 9ºC. The factory-set value is 2ºC.

SVH - AMBIENT PROBE HIGH TEMPERATURE LIMIT

Function to configure the high temperature limit of the ambient probe. The 

thermostat switches off when the ambient probe reaches this temperature. 

Use the       /       symbols to set the value that can range from 5ºC to 99ºC. The 

factory set value is 35ºC.

SVL - AMBIENT PROBE LOW TEMPERATURE LIMIT

Function to configure the low temperature limit of the ambient probe. The 

thermostat switches off when the ambient probe reaches this temperature. 

Use the      /      symbols to set the value that can range from 5ºC to 99ºC. The 

factory set value is 5ºC.

ADJ - CORRECTION OF THE AMBIENT PROBE TEMPERATURE

This function allows to correct the temperature of the ambient probe. This 

correction is applied when the temperature displayed by the room probe is 

not equal to the actual room temperature (measured with another external 

device). This can happen due to the installation or position of the thermostat. 

Use the     /     symbols to set this value. The factory set value is 0ºC.

FRE - ANTI-FREEZE FUNCTION

This function allows to activate or deactivate the anti-freeze function. With 

this function active, the thermostat starts automatically when the tempera-

ture of the ambient probe is below the low temperature limit defined in the 

SVL function. A value of 0 means that the function is off and a value of 1 

means that the function is on.

PON- MEMORY FUNCTION IN CASE OF CURRENT FAILURE

Here you can define whether or not the thermostat should store its settings in 

the event of a power failure. A value of 0 means that the function is off and a 

value of 1 means that the function is on.

FAC - FACTORY SETTINGS

In this function you can reset all settings and functions to the factory default 

values. Use the      /      symbols to set this value. Choosing the value 00 will 

reset all the settings and settings to the factory value. If you do not want to 

make changes, select the value 08.

 

 

Error

Cause

Solution

ERR

Floor Probe Error

 

Replace floor probe

 

 

VIII - ERROR TABLE

GLOBOVAC Ltd.
Address:

 Globovac Ltd, 8C Castle Road, Chelston

Business Park, Wellington, Somerset
TA21 9JQ, United Kingdom

Tel Export: 

+44 (0) 1293 768 210

Tel UK Costumers:

 +44 (0) 1293 772 165

Email:

 [email protected]

Web:

 www.globovac.com

TOGGLE BETWEEN MANUAL AND AUTOMATIC MODE

With the thermostat on, press the symbol         to switch between manual and 

automatic mode. When the thermostat is in automatic mode, the symbol for 

one of the daily settings (    ,     ,     ,     ,    ,    ) will appear on the display. When in 

manual mode, the display shows the symbol        .

DAILY AND WEEKLY SCHEDULE

This thermostat supports 6 daily and 3 weekly settings (5 + 2 days, 6 + 1 days 

or 7 days). If you choose to schedule one of the weekend days separately (5 + 

2 or 6 + 1), you have only 2 daily schedules for that day (s).
With the thermostat on, press the symbol         for 5 seconds. When the word 

“loop” is on the display, you can use the       /        symbols to define the weekly 

interval to be programmed.
Press the symbol          again and the symbol for the first daily schedule will 

appear on the display (    ) together with the temperature to be programmed 

for this time to flash. Use the     /    symbols to set the temperature for this time. 

If you want to change the time for this daily schedule, press the symbol       

and you will have the digit of the hours to flash. Use the    /   symbols to set the 

time. Press the symbol     again and the minute numbers will flash. Use the   / 

symbols to set the minutes. Press the symbol       again if you want to change 

the temperature again for this daily schedule or press the symbol        to move 

to the next daily schedule.
Repeat the same procedure for the remaining 5 daily schedules. If you have 

chosen the weekly mode 5 + 2 or 6 + 1, repeat the procedure described above 

for your daily weekend schedule.

NOTE 1

: daily periods have to be programmed, none of them can be ignored.

NOTE 2

: there is no opening and closing of daily periods. If you do not want 

heating in the room for a certain period, you must program that period with a 

sufficiently low temperature so that the thermostat does not start.

NOTE 3

: during programming, if you do not press any button for 15 seconds, 

the programming process is interrupted. The display returns to the main 

screen and the changes made so far are saved.

NOTE 4

:when the thermostat is operating in automatic mode, you can 

manually change the temperature for that time using the       /       symbols. In 

addition to the automatic mode symbol corresponding to the current daily 

interval (    ,     ,     ,     ,     ,    ), the symbol       is also displayed. Changes you make 

manually in automatic mode are canceled when you start a new daily 

schedule or by pressing the symbol           twice.

CHILD LOCK

With the thermostat on, press the symbol       for 5 seconds and the symbol   

will appear on the display. This will block all touch functions of the thermostat 

and prevent its use. To unlock, press again the symbol      for 5 seconds.

With the thermostat turned off, hold down the symbol        and simultaneously 

press the symbol        to enter the advanced settings menu.

GENERAL FUNCTIONS TABLE

Probe selection
Floor probe temperature limit
Temperature differential associated with the threshold of the floor probe
Ambient probe high temperature limit
Ambient probe low temperature limit
Correction of the ambient probe temperature
Anti-freeze function
Memory function in case of power failure
Factory settings

SEN
OSV
DIF
SVH

ADJ
FRE
PON
FAC

SVL