Technical parameters

Voltage

 

AC 230V, 50-60Hz

Amperage

 

16 A

 

Working environment

 

0ºC ~45ºC 

 

Consumption

 

<0.3 W

 

Protection index

 

IP20

 

Programmable temperature

 

5ºC ~ 60ºC 

 

Temperature control precision

 

0.5 ºC

 

Características Principais

Programs

 

6 daily, 3 weeklys

 

Probe reading options

 

3 (internal, external and both)

 

External dimensions

 

 

85mm x 85mm x 14mm

 

Material

 

PC + ABS

 

Screen background colo

 

Blue

 

Memory in case of electrical failure

 

Time and Programs

 

Child lock

 

Yes

 

Installation

 

Wall-Inserted Type

 

 

III - CAUTIONS FOR INSTALLATION

Fig. 1 - Thermostat opening

1 2 3 4

5

L1 N1

N

L

6

N

TC

Fig. 2 - Wiring diagram

Fig. 3 - Thermostat Installation

Heating

Manual Mode

Anti-Frozen

Child Lock

Probes Temperature

Clock

Buttons

Period

Set temperature
Week

V - THERMOSTAT INTERFACE

+

+

Button functions

Thermostat ON

Long Press

Thermostat OFF

Short Press

Thermostat ON

Short Press

----

Turn on

Turn Off

Daily and weekly

schedule

----

Toggle automatic / 

manual mode

Child Lock

----

Set time and day

Increase temperature

0.5ºC continuously

----

Increase temperature

0.5ºC

Decrease temperature

0.5ºC continuously

----

Decrease temperature

0.5ºC

----

Advanced

Settings

----

----

----

Floor probe reading

VI -  THERMOSTAT PROGRAMMING

TURN ON/OFF

Press the button        to turn on the thermostat.
Press the button        again to turn off the thermostat and cut the power to the 

heating cable or mat.

Dear User:
Congratulations on choosing a           thermostat.  Please refer to this user 

manual before installing/using the thermostat.
This thermostat is used to control the temperature of heating cables or 

heating mats for electric underfloor heating in a given room, wether in a 

domestic, commercial or industrial environment.
While we try to provide the best device possible, we are always available for 

technical support. If you have any questions, please contact us.

II - TECHNICAL PARAMETERS AND MAIN CHARACTERISTICS

ATTENTION!

When being installed, this thermostat may cause an

electric shock. Make sure the installation is done by

a qualified electrician.

1. Installation should only be done when the electric supply is off, otherwise it can 

damage the thermostat and cause an electric shock.
2. Choose the most suitable location for installing the thermostat (about 1,60m 

above the floor). It must not be installed at eye level.
3. Installation should not be made at altitudes higher then 2000m above sea level.

IV - INSTALLATION

1. Separate the thermostat from the display using a screwdriver to press the 

groove at the back of the thermostat and pushing the display upwards (fig.1).
2. Follow the wiring diagram (fig. 2) to connect the power, the heating cable 

and the floor probe.
3. Use the two screws provided to fix the outer ring and the thermostat base 

to the electrician's deep box previously installed (fig. 3) and make sure that it 

is properly installed.
4. Attach the display to the four projections on the mounting plate and push it 

downwards (never press the LCD display directly). The installation is complete. 

Turn on the power to test the thermostat.

Heating Cable / Mat

16A

N (Neutral Wire)

L (Live wire)

AC220V, 50~60Hz

Floor Sensor