I - INTRODUCTION
II - TECHNICAL PARAMETERS AND MAIN CHARACTERISTICS
Technical parameters
Voltage
AC 230V, 50-60Hz
Amperage
16 A
Working environment
0ºC ~70ºC
Consumption
<0.3 W
Protection index
IP20
Programmable temperature
5ºC ~ 35ºC
Temperature control precision
0.5 ºC
Main characteristics
Programs
3 daily, cyclic active scheduling
Probe reading options
3 (internal, external and both)
External dimensions
86mm x 86mm x 27mm
Material
PC + ABS
Screen background color
Blue
Memory in case of electrical failure
Time and schedules
Child lock
Yes
Installation
Wall-Inserted Type
III - CAUTIONS FOR INSTALLATION
IV - INSTALLATION
1. Separate the thermostat from the display using a screwdriver to press the
groove at the back of the thermostat and pushing the display upwards (fig.1).
2. Follow the wiring diagram (fig. 2) to connect the power, the heating cable
and the floor probe.
3. Use the two screws provided to fix the outer ring and the thermostat base
to the electrician's deep box previously installed (fig. 3) and make sure that it
is properly installed.
4. Attach the display to the four projections on the mounting plate and push it
downwards (never press the LCD display directly). The installation is complete.
Turn on the power to test the thermostat.
Fig. 1 - Thermostat opening
1 2 3 4
5
L1 N1
N
L
6
N
TC
Load
IP 20
AC230V 50/60Hz
current imax:16A
Fig. 2 - Wiring diagram
Fig. 3 - Thermostat Installation
Switch on / off thermostat.
Press for 3s to activate / deactivate child lock
Rotate clock wise Increases the Value, Rotate in the opposite direction
Decreases Value
Fast Press Confirms the option (Enter key)
Pressing for 3s, when released, enters settings mode
P
1
P
2
P
3
PROG
TIME
F C
F C
SET
ROOM
NTC
0
6
12
18
24
AUTO
Child lock
Programs 1 2 and 3
Energy Saver Mode
Confort Mode
Heating
Hours
24 hours of the day
Programming Symbol
Days of the week
Advanced Options symbol
Set temperature
Room temperature
Automatic mode
Manual mode
Anti-freeze mode
Vacation Mode
V - THERMOSTAT INTERFACE
Funções dos botões
TIME
VI - THERMOSTAT PROGRAMMING
»
ON / OFF
Press the button to turn on the thermostat (located on the right side of the
thermostat).
Press the button again to turn off the thermostat and cut the power to the
heating cable or network.
»
SETTING THE TIME AND DAY OF THE WEEK
With the thermostat on, press the button and release after 3 seconds to
enter the settings mode.
Turn the knob until the symbol flashes and short press the button
to enter the Hour and day of the week settings.
Rotate the knob to set the minutes and confirm with a short press on the
same button, after the minutes the hours follow with the same procedure.
After setting the hours and pressing the button , you will see the days of
the week flash ( ). 1 represents Monday, 6 represents Saturday
and 7 represents Sunday. After setting the day of the week, press the button
again to exit the menu and wait 5 seconds to exit the settings mode.
Dear User:
Congratulations on chhosing a thermostat. Please refer to this user
manual before installing/using the thermostat.
This thermostat is used to control the temperature of heating cables or
heating mats for electric underfloor heating in a given room, wether in a
domestic, commercial or industrial environment.
While we try to provide the best device possible, we are always available for
technical support. If you have any questions, please contact us.
ATTENTION!
When being installed, this thermostat may cause an
electric shock. Make sure the installation is done by
a qualified electrician.
1. Installation should only be done when the electric supply is off, otherwise it can
damage the thermostat and cause an electric shock.
2. Choose the most suitable location for installing the thermostat (about 1,60m
above the floor). It must not be installed at eye level.
3. Installation should not be made at altitudes higher then 2000m above sea level.
Heating Cable / Mat
16A
N (Neutral Wire)
L (Live wire)
AC220V, 50~60Hz
Floor Sensor