background image

»

SWITCH BETWEEN MANUAL AND AUTOMATIC MODE

With the thermostat on, press the button        quickly to switch between 

manual           and automatic        mode.

»

SET TEMPERATURE IN MANUAL MODE

With the thermostat turned on in manual mode, turn the knob          to set the 

desired temperature.
The thermostat turns on when the probe temperature is lower than the one 

set at 1.5ºC and the symbol         appears on the screen. This symbol means 

that the cable or network is heating up. The thermostat switches off when the 

probe temperature is higher than the one set at 1ºC.

»

PROGRAMMING ENERGY SAVING MODE / COMFORT MODE

With the thermostat on, press the button      for 3 seconds to enter the settings 

mode. Choose between the Energy Saving            option or the Comfort    

option and press the button          quickly to enter the selected option.
Rotate the knob         to select the desired temperature for the selected mode 

and quickly press the button        to return to the settings menu.
Wait 5 seconds to exit the settings menu.

»

DAILY SCHEDULES P1 P2 and P3

With the thermostat on, press the button        for 3 seconds to enter the 

settings mode. Select the symbol                   and quickly press the same button.
It will start at schedule 1 at 00:00, you must turn the button         to select 

between Energy Saver mode and Comfort mode.
Pressing the button          again will switch to 01:00, 02:00 ... until 24:00. After 

24h of program 1, it will go to 00h00 of program 2 and then program 3. The 

settings of the 3 programs are defined.
These programs will run in a cycle, if you choose P1 it will repeat every day.

»

SELECT PROGRAMMING FOR AUTOMATIC MODE

With the thermostat on, press the button          for 3s to enter the settings 

mode. Select the symbol corresponding to the desired programming,            

and quickly press the same button. Quickly press the button again to return to 

the settings menu and wait 5 seconds to exit the settings menu. The selected 

program symbol will appear on the display.

»

VACATION MODE

With the thermostat on, press the button         for 3s to enter the settings 

mode. Select the symbol            and quickly press the same button. it will 

define the number of days it will be absent and after pressing the button 

again it will define the temperature at which the system will work.
Wait 5 seconds and the symbol          will remain on the display.
Pressing the button will alternate between the number of days and the 

desired temperature without leaving the vacation mode.
To cancel the vacation mode, go to the settings mode and select automatic or 

manual mode.

»

CHILD LOCK

Regardless of whether the thermostat is on or off, press the side button        for 

3s. When you release the button, you will see the symbol               on the display 

indicating that the thermostat is locked.
Repeat the same procedure to unlock the thermostat.

P

1

P

2

P

3

Error

Cause

Solution

ERR

Floor probe error

Replace floor probe

AUTO

PROG

A1

Correction of temperature reading

A2

Floor probe limit temperature

A3

Child lock: Partial, Total;

A4

High temperature limit of the floor probe

A5

Ambient probe low temperature limit

A6

Minimum temperature correction of the ambient probe

A7

Programmable maximum temperature limit

A8

Non-programmable options

A9

Anti-freeze function

Enter settings mode and select the symbol                       to enter advanced 

settings, turn to move to the next function.

»

GENERAL FUNCTIONS TABLE

VIII - ADVANCED SETTINGS

VII - ERROR TABLE

AA

Memory (0 - on; 1 - Off)

AB

Temperature Unit (ºC / ºF)

AC

Descaling function (not applicable)

AD

Probes (N1 - room, N2 - floor, N3 - both)

AE

Restore Factory Settings

GLOBOVAC Ltd.