6
3. This appliance requires a standard 220-240Volt, 50Hz electrical outlet with good grounding
means.
Before using your ice maker, it is strongly recommended to clean it thoroughly.
CLEANING AND MAINTAINING YOUR ICE MAKER
1. Take out the ice basket.
2. Clean the interior with diluted detergent, warm water and a soft cloth.
3. Then use the water to rinse the inside parts, and drain out the water by unplugging the drain cap
on the side.
4. The outside of the ice maker should be cleaned regularly with a mild detergent solution and warm
water.
5. Dry the interior and exterior with a soft cloth.
6. When the machine is not in use for a long time, open water drained cap to drain water completely
from water reservoir.
Note
: Blowing gas inside the unit is flammable, disposal of these material shall be in accordance with
national regulations.
USING YOUR ICE MAKER
START TO MAKE THE ICE-CUBE
1. Open the cover, remove the ice basket and pour water into water reservoir.
Keep water level below the level mark.
2. Press “ON/OFF” button on the control panel to turn on the unit to begin the ice making cycle.
3. Select the size of the ice cube by pressing the “Select” button. Three sizes: SMALL, MEDIUM or
LARGE can be selected:
SMALL
MEDIUM
LARGE
If the room temperature is lower than 60°F, it is recommended to select the small or medium ice
sign button in order to avoid ice sticking together.
4. The ice making cycle lasts 6 to 15 minutes, depending on the size of the ice cube selection and
the ambient temperature. In the extreme hot room temperature, ice-making time maybe vary a lot.
5. While the icemaker is on, verify water level periodically. If water pump can’t inject water, the ice
maker will stop automatically, and the „ ” symbol will flash in LCD display window.
Fill water up to the level mark and press “ON/OFF” button two times again to turn on the unit
again. Allow the refrigerant liquid inside the compressor at least 3 minutes to settle before
restarting.
6. The ice maker automatically stops working when the ice basket is full and the „
“ symbol will
display in the LCD display widow.
7. Change water in the water reservoir every 24 hours to ensure a reasonable hygiene level.
If unit isn’t in use, drain all water left in the tank.