H-20/35 VR Series Proportioning Unit
26
42942-VR-1, Issue 1
Cycles per Pump
120 Pump Output lbs.
(kg)
80 Pump Output lbs.
(kg)
5
1.56 (.71)
1.04 (.47)
10
3.12 (1.42)
2.08 (.94)
15
4.68 (2.13)
3.12 (1.41)
20
6.24 (2.84)
4.16 (1.88)
25
7.80 (3.55)
5.20 (2.35)
30
9.36 (4.26)
6.24 (2.82)
35
10.92 (4.97)
7.28 (3.29)
40
12.48 (5.68)
8.32 (3.76)
45
14.04 (6.39)
9.36 (4.23)
50
15.60 (7.1)
10.40 (4.7)
55
17.16 (7.81)
11.44 (5.17)
60
18.72 (8.52)
12.48 (5.64)
13. Repeat step 9.
14. Turn the Pump Mode Switch to RUN.
15. Tighten lock nut on Hydraulic Pump Flow Control Adjustments and replace caps.
NOTE:
Both the locking nut and caps
contain o-ring seals.
16. Close the Recirculating Ball Valves.
If all steps have been followed and no problems have been encountered, the
H-20/35 VR should now be ready for operation.