GAP Pro Spray Gun
12
36943-1, Issue 1
Daily Shutdown Procedure
TOOLS REQUIRED
•
5/16” Spintite
IMPORTANT:
Follow this procedure whenever the gun is out of service for any
length of time.
1.
PERFORM PROPORTIONING UNIT DAILY SHUT-DOWN PROCEDURE
-
2.
CLOSE BOTH MANUAL VALVES-
3.
ENGAGE THE SAFETY STOP-
4.
DISCONNECT THE AIR SUPPLY-
Disconnect the Air Hose from the Quick
Disconnect Fitting on the Air Supply Hose.
Important
Do Not perform steps 4 through 8 if gun is to be serviced following
shutdown.
5.
GREASE MIXING CHAMBER
- Insert the Gusmer GAP Gun Chamber Lubricant
Needle into nozzle of the mixing chamber. Dispense a small amount of lubricant
into mixing chamber.
NOTE:
To determine the correct amount,
to dispense, remove the air cap.
While dispensing view the
chamber area. When lubricant
becomes visible, an adequate
amount has been dispensed.
6.
CONNECT THE AIR SUPPLY
- Connect the Air Hose to the Quick Disconnect
Fitting on the Air Supply Hose.
7.
TRIGGER GUN
- Leave the Safety Stop engaged and trigger the gun 2 to 3 times to
discharge excess lubricant.
8.
DISCONNECT THE AIR SUPPLY-
Disconnect the Air Hose from the Quick
Disconnect Fitting on the Air Supply Hose.