network could communicate with the acquisition module if it was configured
to use an IP address of (for example) 

192.168.0.2

 with a matching netmask

of 

255.255.255.0

.

Note:

  IP addresses assigned using this method will be lost if

the unit is rebooted.   To permanently assign an IP address,
refer   to   the   Platinum   manual,   MAN-EAM-0003,   available
from www.guralp.com

If you wish to connect to the EAM-R from a PC, they must either both be on
the same subnet (usually the first three numbers of the IP address) or be able
to connect to each other via routers.

In the latter case, you will need to tell the acquisition module the address of
its default router.  Please refer to the Platinum manual, MAN-EAM-0003, for
more details.

2.1.4 Discovering dynamically allocated addresses

There are three ways to discover a dynamically allocated address.   You can
read it from the unit's LCD display, you can connect to the serial port and
enquire or you can use a broadcast address in Scream.

2.1.4.1 Using the serial port

To use the serial port, connect a terminal emulator (as described in section
2.1.3 on page 5 and issue the command:

ip addr show dev eth0

You will see output like

eam999 ~ # 

ip addr show dev eth0

2: eth0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc 
pfifo_fast qlen 1000
   link/ether 00:50:c2:40:54:75 brd ff:ff:ff:ff:ff:ff 
   inet 192.168.0.101/24 brd 192.168.1.255 scope global eth0

   inet6 fe80:250:c2ff:fe40:5475/64 scope link 
   valid_lft forever preferred_lft forever 
eam999 ~ #

The first line of the output should contain the word 

UP

, confirming that the

adaptor has been enabled.  The IP address that has been assigned is shown on
the line beginning 

inet

 - in this case, it is 

192.168.0.101

 (with a netmask

of 24-bits indicated by 

/24

).

Error: Reference source not found

6

 Issue A  - February 2012

Содержание CMG-EAM-R

Страница 1: ...ice The information in this manual is proprietary to G ralp Systems Limited and may not be copied or distributed outside the approved recipient s organisation without the approval of G ralp Systems Li...

Страница 2: ...Error Reference source not found Contents furnishing performance or usage of this material Issue A February 2012 Error Reference source not found Issue A February 2012...

Страница 3: ...Hook up diagrams 7 2 2 1 Multiple CD24 R8s with GPS synchronisation 7 2 2 2 Multiple CD24 R8s with GPS synchronisation 8 2 3 Operation 9 2 3 1 The LCD display 9 2 3 2 The FLUSH button 10 2 3 3 Connec...

Страница 4: ...4Mb of RAM and 512Mb of on board flash The unit is equipped with 100BASE TX Ethernet three serial ports and seven USB ports The EAM R runs the open source Linux operating system and G ralp Systems Pla...

Страница 5: ...for example allocate addresses to both systems if the EAM R is connected directly to a laptop running Windows To determine which address has been allocated use one of the techniques described in sect...

Страница 6: ...s There are three ways to discover a dynamically allocated address You can read it from the unit s LCD display you can connect to the serial port and enquire or you can use a broadcast address in Scre...

Страница 7: ...255 255 255 255 this is a broadcast address that will be recognised by all hosts on the network The new server will appear in the Servers list click on it once to highlight it and then key This sends...

Страница 8: ...please see its manual MAN C24 0004 which can be downloaded from www guralp com documents MAN C24 0004 pdf Multiple CD24 R8s can be connected to a single EAM R using USB cables as shown The GPS receive...

Страница 9: ...he ETHERNET connector All other connections are as described in the previous section The EAM R needs to be configured to accept NTP synchronisation and to output NMEA GPS timing signals from the TIME...

Страница 10: ...is section discusses features of the EAM R which differ from or are not mentioned in the Platinum manual 2 3 1 The LCD display The front panel LCD display is not mentioned in the Platinum manual it sc...

Страница 11: ...for each on the System Status page of the web interface and appropriate entries will appear in the instrument control and digitiser configuration menus If the digitisers are connected and powered up...

Страница 12: ...no parity bit and one stop bit Hardware and software flow control are not used These settings can not be changed in the firmware so that access to the configuration system can be gained via this port...

Страница 13: ...nectors are purchased from GSL 3 2 2 Time This is a standard DE9F TIA 574 sub miniature D sub plug conforming to DIN 41652 and MIL DTL 24308 They are very widely available as are suitable mating conne...

Страница 14: ...cted 5 Ground 6 not connected 7 not connected 8 not connected 9 not connected Wiring details for the compatible plug DE9M as seen from the cable end i e during assembly 3 2 4 Ethernet The ETHERNET con...

Страница 15: ...with conventional wiring Suitable mating connectors are widely available USB connections are very sensitive to wiring details so it is recommended that ready made cables are used where possible When u...

Страница 16: ...Error Reference source not found Revision history 4 Revision history 2010 04 28 A New document Error Reference source not found 16 Issue A February 2012...

Отзывы: