background image

4. Switching on the units

You start the CATCenter as well as the UCON/s via the rocker switch at the back of the 
devices. 

5. Login to the system

After starting the CATCenter, the 
LOGIN window  appears. Enter your 
USER name and your personal 
USER password here.

This information can be obtained 
by your administrator

6. Automatic video adjustment

After you have started the system and switched to a PC for the first time, for this PC a 
video profile will be automatically generated.  

If this video profile doesn´t meet your requirements an individual video adjustment can be  
carried out (OSD -> Configuration-> Video). Proceed as described as of chapter 5.4 of the 
manual CATCenter - Operation“!  

7. Switching between the connected devices

In order to switch between the devices connected to the UCON/s (local PC or access to 
the CATCenter) you can use the three buttons at the front of the UCON/s . 

The buttons at the front serve for the following:

PC 1: 

Switch to the first local PC

PC 2: 

Switch to the second local PC

Trans:  This button accesses the Transmission interface at the back of the UCONs.  This 

button serves to establish a direct connection to the CATCenter. Subsequently, 
you can perform any further operating steps, as described as of chapter 2 of the 
manual CATCenter - Operation“!  

8. Technical Information UCON/s

See manual CATCenter - Installation“, chapter 5.2

Содержание UCON/s

Страница 1: ...UCON s Kurzanleitung Inbetriebnahme UCON s copyright G D 24 08 2005 Irrum und techn Änderungen vorbehalten ...

Страница 2: ...are miteinander verbinden Stellen Sie vor Inbetriebnahme zunächst die Verbindungen gemäß der unten abgebildeten Zeichnung her 2 1 Anschluss der lokalen Konsole 2 2 Anschluss der lokalen Rechner 2 3 Verbindung zwischen UCON s und CATCenter herstellen auch im laufenden Betrieb des CATCenter möglich Lokaler Konsolenanschluss über PS 2 Schnittstellen und VGA 1 1 Direktverbindung zwischen UCON s Schnit...

Страница 3: ...o Verfahren Sie hierfür wie ab Kapitel 5 4 des Handbuches CATCenter Bedienung beschrieben 7 Umschalten zwischen den angeschlossenen Geräten Der Wechsel zwischen den an der UCON s angeschlossenen Geräten lokaler Rechner oder Zugang zum CATCenter erfolgt über die drei Taster auf der Frontseite der UCON s Die Taster auf der Frontseite haben folgende Bedeutung PC 1 Aufschalten auf den ersten lokalen R...

Страница 4: ...e n t w i c k l u n g G e r m a n y Dortmunder Str 4a Tel 49 2739 8901 100 57234 Wilnsdorf Fax 49 2739 8901 120 http www GDsys de Mail sales GDsys de e Sun MAC RS 6000 HP 9000 SGI DEC Alpha Station sind eingetragene Warenzeichen der jeweiligen Hersteller ...

Страница 5: ...UCON s Getting started UCON s copyright G D 24 08 2005 Errors and technical changes excepted ...

Страница 6: ...tween UCON s Interface Transmission and CATCenter any console interface via a CAT x patch cabel Connection of local PCs max 2 3 Power Supply Connect the power cords to the sockets Main POWER of the devices CATCenter and UCON s As an option you can connect a redundant power pack to the socket Red Power For this purpose you can use the Power Set 12 Typ1 to be ordered separately 2 3 2 2 1 What you ne...

Страница 7: ...rried out OSD Configuration Video Proceed as described as of chapter 5 4 of the manual CATCenter Operation 7 Switching between the connected devices In order to switch between the devices connected to the UCON s local PC or access to the CATCenter you can use the three buttons at the front of the UCON s The buttons at the front serve for the following PC 1 Switch to the first local PC PC 2 Switch ...

Страница 8: ...e n t w i c k l u n g G e r m a n y Dortmunder Str 4a Tel 49 2739 8901 100 57234 Wilnsdorf Fax 49 2739 8901 120 http www GDsys de Mail sales GDsys de e Sun MAC RS 6000 HP 9000 SGI DEC Alpha Station are registered trademarks of the respective manufactorer ...

Отзывы: