2. Installation of the hardware

Before usage of the system make sure, that the mentiond installation steps have been 
carried out according to the drawing below:

2.1 Connection of the local console
2.2 Conncetion of the local PCs
2.3 Establish connection between UCON/s and CATCenter

Local console connection over PS/2-
Interfaces and VGA 

   

1:1-connection between UCON/s (Interface Transmission) and 
CATCenter (any console interface) via a CAT-x patch cabel .

Connection of local PCs (max. 2)

3. Power Supply

Connect the power cords  to the sockets Main  POWER  of the devices (CATCenter, and UCON/s). 

As an option, you can connect a redundant power pack to the socket Red. Power. For this 
purpose, you can use the Power-Set 12/Typ1 to be ordered separately.

2.3

2.2

1. What you need before installing

- UCON/s
- 1:1 CAT-x patch cabel
- CAT

PRO

2 (for connection of local PC)

- Power Cord
- Configuration password – can be obtained by your administrator

CAT

PRO

2

(Alternativly keyboard and mouse 
can be connected via USB)

Содержание UCON/s

Страница 1: ...UCON s Kurzanleitung Inbetriebnahme UCON s copyright G D 24 08 2005 Irrum und techn Änderungen vorbehalten ...

Страница 2: ...are miteinander verbinden Stellen Sie vor Inbetriebnahme zunächst die Verbindungen gemäß der unten abgebildeten Zeichnung her 2 1 Anschluss der lokalen Konsole 2 2 Anschluss der lokalen Rechner 2 3 Verbindung zwischen UCON s und CATCenter herstellen auch im laufenden Betrieb des CATCenter möglich Lokaler Konsolenanschluss über PS 2 Schnittstellen und VGA 1 1 Direktverbindung zwischen UCON s Schnit...

Страница 3: ...o Verfahren Sie hierfür wie ab Kapitel 5 4 des Handbuches CATCenter Bedienung beschrieben 7 Umschalten zwischen den angeschlossenen Geräten Der Wechsel zwischen den an der UCON s angeschlossenen Geräten lokaler Rechner oder Zugang zum CATCenter erfolgt über die drei Taster auf der Frontseite der UCON s Die Taster auf der Frontseite haben folgende Bedeutung PC 1 Aufschalten auf den ersten lokalen R...

Страница 4: ...e n t w i c k l u n g G e r m a n y Dortmunder Str 4a Tel 49 2739 8901 100 57234 Wilnsdorf Fax 49 2739 8901 120 http www GDsys de Mail sales GDsys de e Sun MAC RS 6000 HP 9000 SGI DEC Alpha Station sind eingetragene Warenzeichen der jeweiligen Hersteller ...

Страница 5: ...UCON s Getting started UCON s copyright G D 24 08 2005 Errors and technical changes excepted ...

Страница 6: ...tween UCON s Interface Transmission and CATCenter any console interface via a CAT x patch cabel Connection of local PCs max 2 3 Power Supply Connect the power cords to the sockets Main POWER of the devices CATCenter and UCON s As an option you can connect a redundant power pack to the socket Red Power For this purpose you can use the Power Set 12 Typ1 to be ordered separately 2 3 2 2 1 What you ne...

Страница 7: ...rried out OSD Configuration Video Proceed as described as of chapter 5 4 of the manual CATCenter Operation 7 Switching between the connected devices In order to switch between the devices connected to the UCON s local PC or access to the CATCenter you can use the three buttons at the front of the UCON s The buttons at the front serve for the following PC 1 Switch to the first local PC PC 2 Switch ...

Страница 8: ...e n t w i c k l u n g G e r m a n y Dortmunder Str 4a Tel 49 2739 8901 100 57234 Wilnsdorf Fax 49 2739 8901 120 http www GDsys de Mail sales GDsys de e Sun MAC RS 6000 HP 9000 SGI DEC Alpha Station are registered trademarks of the respective manufactorer ...

Отзывы: