Installation and Maintenance guide

V80-3P/V130-3P/V250-3P

EN

________________________________________________________________________________________________

Rev. 2015.1

Содержание V130-3P

Страница 1: ...Installation and Maintenance guide V80 3P V130 3P V250 3P EN ________________________________________________________________________________________________ Rev 2015 1 ...

Страница 2: ...ld responsible for damage resulting from incorrect installation incorrect fault tracing or incorrect maintenance Yours sincerely Gullberg Jansson AB Subject to possible misprints and design alterations Gullberg Jansson AB is not responsible for misinterpretations any obvious misprints and consequences resulting from these FOR YOUR OWN RECORDS Please complete the details below Keep these close to h...

Страница 3: ...pling 8 Interconnection of multiple units 8 Electrical installation 9 Starting up the unit 9 Use and operation LCD display 10 Start screen 10 Temperature setting 10 Main menu 11 Temperature values 11 Digital inputs 11 Relay outputs 11 About the software 11 Setting time and date 12 Error messages 12 Maintenance service and fault tracing Winter drainage 13 Maintenance 13 Fault tracing 13 Error code ...

Страница 4: ...ifferent efficiency during different parts of the year depending on the outdoor conditions At the start of the season when the water in the pool is cold the heat pump needs to work continuously for a long period to produce the right temperature in the pool When the pool water has reached the required temperature the heat pump automatically stops and starts as required It is always cost effective t...

Страница 5: ...ly to the pool heat pump If the solar collector water becomes too hot you risk damaging the heat pump beyond repair Use and operation The parameters on the display are set at the factory and do normally not need to be adjusted The temperature is set to 27 C If you wish to increase the temperature check first to ensure that your wishes of a high temperature do not contravene any guarantees concerni...

Страница 6: ...nergise and check the settings Put in operation and adjust the flow to the pool heat pump to the right level Read more about start up in section 2 under the heading Starting up the unit Guarantee conditions The component parts of the system must be transported stored and installed in accordance with the provisions set out in the manual Repairs must be carried out by a qualified engineer Original p...

Страница 7: ... be placed on a firm horizontal base and should not be placed next to or be installed with brackets on sensitive walls with a lightweight structure The unit must be placed so that noise from the compressor and fan disturb the surroundings as little as possible The unit must stand firmly straight and raised from ground level Ensure a firm and flat surface is provided Large amounts of melt and conde...

Страница 8: ...ool heat pump Adjusting the bypass 1 Open all the valves 2 Check the incoming and outgoing water temperature see Section 3 a If there is no difference in temperature gradually close the supply valve until the difference is between 1 and 2 degrees b If the difference is above 2 degrees gradually close the bypass valve until the difference is between 1 2 degrees If the display shows E03 this means t...

Страница 9: ... pool heat pump 2 Switch on the supply voltage press ON OFF on the display and the unit will start up after a few seconds 3 After a few minutes check that temperatures T03 and T04 are lower than T05 4 Stop the pool s circulation pump and make sure that the pool heat pump stops automatically and displays the error E32 Also check that the heat pump starts again automatically when the circulation pum...

Страница 10: ...temp 26 5 C Outlet temp 27 5 C 24 12 2014 18 08 TUE Start screen The start screen displays the current operating mode and if the unit is OFF or ON To switch between cooling heating and automatic mode press M In order to switch between on and off press the ON OFF button and hold in for at least 1 second The start screen also displays the current inlet and outlet temperature In addition the current ...

Страница 11: ...06 Flow switch CL S07 Elec overload OP S08 Comp 1 overload OP Temperature Switch Output About S09 Comp 2 overload OP S10 Remote switch CL S11 Mode switch CL S12 System protect CL S13 Water flow 0m3 h S14 Class Master Digital inputs Select Switch and press M to display the current values of the digital inputs O01 Compressor 1 OFF O02 Compressor 2 OFF O03 High fan OFF O04 Low fan OFF O05 Circulate p...

Страница 12: ...re multiple simultaneous errors you can view the actual error messages by pressing See examples of error messages below A complete list can be found in Section 4 E03 Water flow failure Failure number 3 Error messages Timer zone Daily timer Timer 1 06 30 12 30 Timer 2 06 30 12 30 Timer 3 06 30 12 30 Timer 4 06 30 12 30 Timer zone Daily timer Mon NONE Tue NONE Wed NONE Thu NONE Fri NONE Sat NONE Sun...

Страница 13: ...information on rectifying the most common problems Always read this before contacting the engineer who completed the installation In the event of any uncertainty before winter drainage contact your dealer An iced up heat exchanger due to forgotten winter drainage is not covered by the guarantee Operating disturbance Cause Action Set pool temperature not reached 1 The heat pump is off 2 The heat pu...

Страница 14: ...e pressostat circuit 1 E11 Refrigerant pressure too high Restart the unit If the error persists contact your installer High pressure pressostat circuit 2 E21 Refrigerant pressure too high Restart the unit If the error persists contact your installer Low pressure pressostat circuit 1 E12 Refrigerant pressure too low Restart the unit If the error persists contact your installer Low pressure pressost...

Страница 15: ...I 06 DI 05 DI 04 DI 03 DI 02 AI 12 50 AI 09 AI 08 AI 06 AI 05 AI 04 AI 03 AI 02 AI 01 5V DI 01 NET 12V DI DO 2 DI DO 1 AI 11 50 GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND CN5 CN1 AI 10 GND Nr Label Description 20 AI07 GND Condensing temp circuit 2 analogue input 21 AI08 GND Suction gas temp circuit 1 analogue input 22 AI09 GND Suctio...

Страница 16: ...2 ET2 1 3 2 4 5 6 7 8 02 4V2 4V1 4V1 4V2 N N 4V N N 4V N N N AI 10 GND EEV1 5 EEV2 5 KM5 K5 K5 N N FS TO POWER SUPPLY 400V 3N 50Hz WHT BLU BLK RED BLK WHT RED BLK WHT Remote Cool heat ON OFF input N PH1 PH2 1 3 2 4 5 6 7 8 03 L13 N N N L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L12 ON OFF output N FM1 RED WHT FM2 RED WHT K3 F K3 L2 FS KM5 N N P1 L1 L2 L3 L2 L1 L3 P3 P2 P1 P3 P2 F L2 L1 N To pump L2...

Страница 17: ...mption W 260 x 2 260 x 2 Rated air flow m3 h 12 400 12 400 Noise level2 dB A 61 61 Water connection mm 63 63 Rated water flow m3 h 13 0 19 0 Pressure drop at rated flow bar 0 12 0 15 Pressostat break value HP bar 44 makes again at 32 bar Pressostat break value LP bar 0 2 bar makes again at 1 5 bar Height mm 1130 1130 Width mm 1490 1490 Depth mm 735 735 Weight kg 230 272 1 Heating output measured a...

Страница 18: ...2 ET1 ET1 ET2 ET2 1 3 2 4 5 6 7 8 03 4V2 4V1 4V1 4V2 N N 4V N N 4V N N L1 L2 N AI 10 GND EEV1 5 EEV2 KM5 L1 L2 L3 N N N P1 TO PUMP KM5 K5 K5 N N KM3 L3 FOHP1 FOHP2 TO POWER SUPPLY 400V 3N 50Hz BLK WHT BLU RED BLK WHT RED BLK WHT Remote out Remote Cool heat Remote in N PH1 PH2 1 3 2 4 5 6 7 8 04 PH N N N L2 L3 L1 L2 L3 L32 L33 L31 L32 L33 L31 1 L31 2 L32 1 L32 2 L33 1 L33 2 L1 L2 L3 L1 L2 L3 L1 L2 ...

Страница 19: ...evel2 dB A 69 Water connection mm DIN 110 Rated water flow m3 h 22 8 Pressure drop at rated flow bar 0 16 Pressostat break value HP bar 44 makes again at 32 bar Pressostat break value LP bar 0 2 bar makes again at 1 5 bar Height mm 2030 Width mm 2175 Depth mm 1070 Weight kg 648 1 Heating output measured at 24 C 19 C outdoor temperature DB WB Dry bulb Wet bulb Incoming water temperature 27 C 2 Heat...

Страница 20: ...____________________________________________________________________ Gullberg Jansson AB Smältaregatan 6 SE 263 39 Höganäs Tel 46 0 42 311 15 00 Fax 46 0 42 34 02 10 E mail info gullbergjansson se www gullbergjansson se Rev 2015 1 ...