9
Installation
A comprehensive installation description is provided in this chapter. This chapter is primarily intended for installation engineers, but
can also be read by the end user to increase his/her knowledge.
2
Positioning the unit
The pool heat pump will work ideally under the following
conditions:
;
Access to fresh air.
;
High enough water circulation.
;
Correct electrical installation.
In principle the pool heat pump can be placed anywhere
outdoors. However, do not place the pool heat pump
enclosed with restricted access to the air intake and air
exhaust (see the figure below). A structure with a roof is not
necessary. If you still want to incorporate the pool heat pump,
remember that exhaust air must be ventilated properly! This
applies particularly to the vertical models.
See illustration below for positioning the pool heat pump.
Set up
The pool heat pump must be placed on a firm, horizontal
base and should not be placed next to or be installed with
brackets on sensitive walls with a lightweight structure. The
unit must be placed so that noise from the compressor and
fan disturb the surroundings as little as possible.
The unit must stand firmly, straight and raised from ground
level. Provide a firm and flat surface, for example, a ground
stand, a garden slab, concrete bed, Leca blocks or similar.
Note that the wooden pallet that the pool pump is resting on
for delivery is to be removed during installation.
Large amounts of melt and condensation water are
discharged during defrosting and operation, which is
entirely normal. Consequently, it is important to ensure good
drainage and run-off. Up to 10 litres of condensation water
per hour can form during operation.
The outdoor section must be placed so that the air supply
to the evaporator coil is sufficient. This produces a higher
output and improved efficiency.
Outline diagram
Air intake
2500mm
700mm
300mm
500mm
700mm
Refer to the labels on the unit before connecting the inlet and outlet.
POOL
Chlorinator
Sand filter
Circulation pump
Positioning of a horizontal model
Содержание X15
Страница 29: ...Vatteninlopp Vattenutlopp Ellucka Mått och anslutningar Teknisk beskrivning 29 Ø50 Ø50 X60 X60 3P Jnverter mm ...
Страница 58: ...Vandindløb Vandudløb Koblingsboks Mål og tilslutninger Teknisk beskrivelse 58 Ø50 Ø50 X60 X60 3P Jnverter mm ...
Страница 87: ...Vanninnløp Vannutløp Koblingsboks Mål og tilkoblinger Teknisk beskrivelse 87 Ø50 Ø50 X60 X60 3P Jnverter mm ...
Страница 116: ...Water inlet Water outlet Junction box Dimensions and connections 116 Ø50 Ø50 X60 X60 3P inverter mm 83900148 ...