Technical data
113
Model
X15
inverter
X20
inverter
X30
inverter
X30-3P
inverter
Heat output
1
kW
1,6-8,4
2,3-11,0
2,5-12,7
2,5-12,7
Heating capacity
2
m
3
20-40
35-55
50-75
50-75
Input power
kW
0,25-1,65
0,38-2,40
0,35-2,66
0,35-2,66
Operating voltage
V~50Hz
230V 1N
400 V 3N
Operating current
3
A
1,6-6,7
2,0-9,8
2,1-11,7
,
,
Fuse size. Type C
A
10
16
3x10
COP
6,4-5,1
6,1-4,6
7,1-4,8
7,1-4,8
Refrigerant quantity (R32A)
kg
0,5
0,
0,
0,
Compressor
Mitsubishi DC Inverter Twin Rotary
Expansion
Electronic expansion valve
Heat exchanger
Titanium heat exchanger
Fan motor
Brushless DC motor
Cabinet
Grey painted steel cabinet
Noise level (at 1 m)
dB(A)
39-47
39-48
39-50
39-50
Water connection
mm
50 mm
m
3
/h
3,5
4,7
5,4
5,4
Pressure drop at nominal
bar
0,02
0,03
0,05
0,05
Pressostat breaking value HP
bar
44 (switch closes again at 32 bar)
Pressostat breaking value LP
bar
1,5 (switch closes again at 3.0 bar)
Height
mm
768
768
862
862
Width
mm
1046
1046
1161
1161
Depth
mm
453
453
490
490
Weight
kg
65
74
90
1
humidity of 70 % and a pool temperature of 26 °C, in accordance with the French pool heat pump standard
NF 414.
2
Heating capacity should be regarded as guide values for an insulated pool covered at night. The models are
primarily designed for use during the period May to September which is a normal pool season.
3
temperature of 26 °C. The operating current may vary depending on the above conditions.
Содержание X15
Страница 29: ...Vatteninlopp Vattenutlopp Ellucka Mått och anslutningar Teknisk beskrivning 29 Ø50 Ø50 X60 X60 3P Jnverter mm ...
Страница 58: ...Vandindløb Vandudløb Koblingsboks Mål og tilslutninger Teknisk beskrivelse 58 Ø50 Ø50 X60 X60 3P Jnverter mm ...
Страница 87: ...Vanninnløp Vannutløp Koblingsboks Mål og tilkoblinger Teknisk beskrivelse 87 Ø50 Ø50 X60 X60 3P Jnverter mm ...
Страница 116: ...Water inlet Water outlet Junction box Dimensions and connections 116 Ø50 Ø50 X60 X60 3P inverter mm 83900148 ...