Technical data
44
Technical specification
A
B
C
F
D
E
OUTLET
INLET
Model
Dim.
GJPASRW-12/15
GJPASRW-20
A
286
390
B
600
694
C
900
905
D
550
650
E
970
985
F
310
420
Dimensions and connections
Model
GJPASRW-12
GJPASRW-15
GJPASRW-20
Heating output
1
kW
5.0
6.5
9.0
Input power
kW
0.95
1.2
1.7
Heating capacity
2
m
3
15 - 25
20 - 30
30 - 45
Operating voltage
230 VAC 1-phase 50 Hz
Operating current
A
4.2
5.23
7.50
Fuse size
A
10
Compressor
Rotary compressor
Refrigerant amount (R410a)
kg
0.8
0.9
1.0
Fan consumption
W
50
50
75
Rated air flow
m
3
/h
1600
1600
2300
Noise level (1 m)
dB(A)
47
47
51
Water connection
mm
50 mm
Rated water flow
m
3
/h
1.8
2.2
3
Pressure drop at rated flow
bar
0.12
0.12
0.10
Pressostat breaking value HP
bar
44 (makes again at 32 bar)
Pressostat breaking value LP
bar
0.2 (makes again at 1.5 bar)
Height
mm
550
550
650
Width
mm
970
970
985
Depth
mm
310
310
420
Weight
kg
53
55
61
1
Heating output measured at 24 °C / 19 °C outdoor temperature, DB / WB (Dry bulb / Wet bulb).
Incoming water temperature 27 °C.
2
Heating capacity should be seen as guide values for an insulated pool covered at night. The
models are designed for use during the period May - September (normal pool season).