© G
ul
dm
an
n GB/US-2583/04/2022 • # 558526_3
© G
ul
dm
an
n GB/US-2583/04/2022 • # 558526_3
9
The emergency lowering must be used in emergencies only. This requires
qualified assistance.
You must contact the dealer before using the LP7 & the LP7+ again. Remove
the key after installation and keep it with the manual.
The electric emergency lowering device is activated by turning the key switch
to the left for 10 seconds. The lifting platform will then begin its descent. The
lifting platform will stop if the key is released. If the key is not activated for 10
seconds, the electrical emergency lowering device will be deactivated, after
which it can be activated again.
The switch is located in the left tower on the lifting platform.
Description of emergency lowering – access ramp
The access ramp is fitted with a
hexagonal screw on the left side.
Remove this screw and the access
ramp can be closed up.
Important!
When the screw is removed from the
access ramp, the ramp can no longer
be secured. Hold onto the access
ramp when removing the screw.
Safety curtain
The safety curtain ensures that nobody can move beneath the lifting platform
when it is at its high est level and thereby risk getting trapped when the lifting
platform is lowered. The safety curtain is fitted upon delivery.
If the safety curtain has not been installed, or if it is damaged and the area
beneath the lifting platform cannot be accessed, the lifting platform cannot be
used until the problem has been solved.