PAGE 4 REV.0 CODE G503155E
4. OPERATING MODES.
The following describes the configuration of various operating modes for the R3660 adaptor.
4.1 ACTIVATION OF THE ADAPTOR RELAY ON RECEIVING A CALL FROM A DWELLING
This operating mode activates the R3660 adaptor output relay when it detects that a dwelling is receiving a call. Thus,
for example, a warning light or a siren, external bell, etc, can be switched on to increase awareness of the call. The
configuration for this is as follows:
SWITCH A:
configured with the
dwelling number
(in the diagram, dwelling number
5).
It can also be configured with its own number, without needing to be
associated with a dwelling.
SWITCH B:
switches 3 and 4
must be configured in the
ON
position. The rest must
remain OFF.
If the adaptor is not associated with any dwelling
(number configured
in switch A),
switch 5
must be set to the
ON
position (main).
SWITCH C:
switches 1, 2, 3, 4 and 5
must be configured to the OFF position. The
positions of switches 6, 7 and 8 define the end of the relay activation (see section 5).
In the diagram, it ends by time in the range 1 to 15 seconds, adjustable with the
potentiometer.
The connections diagram for this operating mode is shown in
FIGURE 1
(page 5).
4.2 ACTIVATION OF THE ADAPTOR RELAY WHEN THE STREET PANEL GENERATES A CALL TO
ANY DWELLING
In this configuration any external element can be activated, such as a camera, a lift call, auxiliary lighting, a siren, etc,
when a call is made from the street panel to any dwelling. The R3660 will activate the output relay when it detects a
call being made from the street panel defined in the configuration. The configuration is:
SWITCH A:
configured with the
street panel number
(in the diagram, street panel
number 1).
SWITCH B:
switches 2 and 3
must be set to the
ON
position. The rest must remain
OFF.
SWITCH C:
switches 1, 2, 3, 4 and 5
must be set to the OFF position. The positions
of switches 6, 7 and 8 define the end of the relay activation (see section 5). In the
diagram, it ends by time in the range 0 to 5 minutes, adjustable with the potentiometer
The connections diagram for this operating mode is shown in
FIGURE 1
(page 5).
4.3 ACTIVATION OF THE ADAPTOR RELAY WHEN THE DOOR LOCK IS RELEASED
This configuration allows the activation of external elements such as an automatic door, an auxiliary light, etc, when
the street panel receives the order to open the door. The switches must be set as follows:
SWITCH A:
configured with the
street panel number
installed in the access (in the
diagram, panel number 1).
SWITCH B:
switches 2, 3 and 4
must be in the
ON
position. The rest must remain
OFF.
SWITCH C:
switches 1, 2, 3 and 4
must be set in the
OFF
position and
switch 5
in
the
ON
position. The positions of switches 6, 7 and 8 define the end of the relay
activation (see section 5). In the diagram, it ends by time in the range 0 to 15
seconds, adjustable with the potentiometer.
The connections diagram for this operating mode is shown in
FIGURE 1
(page 5).
3
SWITCH A
1
2
7
8
6
4
5
1
2
SWITCH B
3
5
6
8
7
1
2
SWITCH C
3
4
5
6
8
7
4
3
SWITCH A
1
2
7
8
6
4
5
1
2
SWITCH B
3
5
6
8
7
1
2
SWITCH C
3
4
5
6
8
7
4
3
SWITCH A
1
2
7
8
6
4
5
1
2
SWITCH B
3
5
6
8
7
1
2
SWITCH C
3
4
5
6
8
7
4