Troubleshooting
Symptom
Possible Cause
Remedy
No spray
Nozzle clogged
Clean the nozzle
Suction pipe clogged
Clean the suction pipe
Flow rate set too low
Turn the adjusting knob clockwise (+)
to increase the flow rate
Suction pipe loosened
Tighten the suction pipe
Tank not tightened
Tighten the tank
Paint is too thick
Check the viscosity of the paint and
dilute.
Paint dropped
from nozzle
Nozzle loosened
Tighten the nozzle
Worn nozzle
Replace the nozzle
Paint accumulated on air
cap or nozzle
Clean the air cap or nozzle with
solvents or water.
Spraying too thick
Paint is too thick
Check the viscosity of the paint and
dilute.
Flow rate set too high
Turn the adjusting knob counter-
clockwise (-) to decrease the flow
rate
Low pressure in the tank
Re-tighten the tank
Irregular spraying
Not enough paint in the
tank
Add enough paint
Dirty filter
Clean the filter or replace it.
Liquid dripping
while spraying
Flow rate set too high
Turn the adjusting knob counter-
clockwise (-) to decrease the flow
rate