5
If the in-line 6 amp fuse blows due to improper connection to a battery, replace the
fuse with an identical 6-amp fast-blow fuse only. Never replace a blown fuse with a
higher value fuse.
The 2603 is completely waterproof, however the AC plug and DC clip-on connections
should be kept dry.
5. MAINTAINING THE CHARGER
Periodically clean both battery terminals with baking soda and tighten all connections.
No other maintenance on the charger is required.
6. TROUBLESHOOTING
Problem
Cause
Solution
1.
Charger does not seem
to be charging batteries
properly.
1.
Batteries too large for the
charger to support or too
many batteries attached
to charger.
2.
Red LED is off due to a
DC overload or a DC
short.
3.
One or more defective
batteries.
4.
Component failure.
1.
Install a higher
Amperage battery
Charger or a second
Charger.
2.
Remove source of
overload or short and
perform the reset
procedure as described
under “Operation”.
3.
Test batteries and replace
if necessary.
4.
Check battery
manufacturer’s charging
specifications.
5.
Return charger to Guest
Service department.
2. Static on TV or radio
whenever the charger is
turned on.
1.
Certain TV’s and
Radios are
Unusually sensitive
To RF interference.
2.
Charger is mounted
within 3 feet of TV or
radio.
1.
Increase the distance
between the charger and
the TV or radio.
2.
Connect TV or radio to an
AC circuit other than the
AC circuit used by the
charger.