background image

 

Red or white wire with in-line fuse to battery (+) 
Black wire to battery (-) 
The in-line fuse holder houses a 3 AMP fuse.  If the battery is connected in reverse (red to (-), black 
to (+)) this fuse will blow, and there may be no LED indication of malfunction. 

WARNING 

Do  not  cut off  or  rewire  the  DC  output  connector.    Failure  to  abide  could cause 
personal injury and void the warranty. 
 
Making AC Plug Connection 

After  securing  the  battery  connections,  plug  the  AC  line  cord  into  an  available  AC  outlet  that  is 
protected by a Ground Fault Circuit Interrupter (GFCI) breaker.  Keep the AC power cord connection 
as short as possible especially when using an extension cord. 

 

4. OPERATING THE CHARGER 

 
Proper Operation 

When the 2602A-12 charger senses a drop in battery voltage, it automatically increases its output to 
re-charge the battery.  By using a sophisticated three-stage charging method, it can fully recharge 
your batteries in the fastest, healthiest way. 

 

During  the  first  charging  stage,  known  as  “

BULK

”  charging,  most  of  the  battery  charging  is 

accomplished.  The green LED will blink during this stage.  The charging current is limited to 2 Amps 
and the battery voltage rises to approximately 14.5 VDC. 

 

During  the  second  charging  stage,  known  as  “

ABSORPTION

”  charging,  the  charger  holds  the 

battery  voltage  at  approximately  14.5  VDC,  and  then  gradually  reduces  the  amount  of  current 
(Amps) it delivers to the battery.  By doing this, the battery is able to “absorb” the last 10% of charge 
as quickly as possible without becoming overheated.  The green LED will blink during this stage. 

 

When  the  battery  approaches  full  charge,  the  charger  switches  into  its  third  charging  stage, 
gradually  reducing  the  current  fed  to  the  batteries  to  as  low  as  0.1  Amps.    At  the  same  time,  it 
reduces its output voltage to a “

FLOAT

” or “

Maintenance

” charging rate of approximately 13.3 VDC 

nominal, indicated by the green LED light.  This low “

Float”

 or 

“Maintenance”

 voltage gently “tops off” 

your batteries, keeping them fully charged and ready until needed.  Now you can store your batteries 
at full charge indefinitely without overcharging, when batteries are properly maintained.  The green 
LED indicates that your batteries are now fully charged and ready for use. 
 
 
 
 
 
 
 
 

Содержание 2602A-12

Страница 1: ...R A Valley Forge Company MODEL 2602A 12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS ...

Страница 2: ...THE VICINITY OF LEAD ACID BATTERIES IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL OPERATION THEREFORE IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY Personal Safety Precautions Adhere to the following personal safety precautions when installing or working with the chargers 1 Someone should be within voice...

Страница 3: ...on DANGER Do not operate this charger with a two bladed ground adapter plug or extension cord Doing so can result in serious personal injury CAUTION To reduce the risk of shock connect only to a properly grounded outlet 3 INSTALLING THE CHARGER Choosing Mounting Location The charger should have at least eight inches of unobstructed area on all sides of the unit for effective cooling The case of th...

Страница 4: ...f the battery charging is accomplished The green LED will blink during this stage The charging current is limited to 2 Amps and the battery voltage rises to approximately 14 5 VDC During the second charging stage known as ABSORPTION charging the charger holds the battery voltage at approximately 14 5 VDC and then gradually reduces the amount of current Amps it delivers to the battery By doing this...

Страница 5: ...ll DC equipment while charging 4 Connect AC power or reset the AC breaker on the main panel 2 The green LED does not stay lit after 24 Hrs of charging 1 On board DC systems are drawing between 1 to 2A 2 One or more defective or damaged cells 3 Extremely low AC voltage at the battery charger 1 Turn off all DC equipment while charging 2 Load test the battery and replace if necessary 3 Apply a higher...

Страница 6: ... 0 1 Amps Input Rated AC Voltage 115 VAC 60 Hz Current Draw 1 0 Amps at full output Maximum recommended battery size For recharging Up to 30 Amp Hours Maintenance only Up to 100 Amp Hours Physical Dimensions Height 2 9 in 7 3 cm Width 5 1 in 12 9 cm Depth 1 5 in 3 8 cm Weight 2 0 lb 0 9 kg ...

Страница 7: ...r relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected LIMITED WARRANTY For two 2 years from the date of original purchase The Guest Co will at its discretion repair or replace for the original consumer free of charge any parts found defective in material or...