Specifications
Resettable Reverse Reactive Energy counter.
epc1202OVPIndex
.43.1.5.2.1.1.x
Integer32
RO
None
epc1202OVPStatus
.43.1.5.2.1.2.x
INTEGER
RO
shows the status of the built-in Overvoltage Protection
epc1202SensorIndex
.43.1.6.1.1.1.x
Integer32
RO
None
epc1202TempSensor
.43.1.6.1.1.2.x
Integer32
RO
actual temperature
epc1202HygroSensor
.43.1.6.1.1.3.x
Integer32
RO
actual humidity
epc1202InputSensor
.43.1.6.1.1.4.x
INTEGER
RO
logical state of input sensor
epc1202AirPressure
.43.1.6.1.1.5.x
Integer32
RO
actual air pressure
epc1202DewPoint
.43.1.6.1.1.6.x
Integer32
RO
dew point for actual temperature and humidity
epc1202DewPointDiff
.43.1.6.1.1.7.x
Integer32
RO
difference between dew point and actual temperature (Temp -
DewPoint)
4.5.2
Device MIB 1292
Below is a table of all device-specific OID 's which can be accessed via SNMP. In the
numerical representation of the OID the prefix " 1.3.6.1.4.1.28507 " (Gude Enterprise
OID) was omitted at each entry in the table to preserve space. The example for a com-
plete OID would be "1.3.6.1.4.1.28507.50.1.1.1.1". A distinction is made in SNMP OID
's in between tables and scalars. OID scalar have the extension ".0" and only specify a
value. In SNMP tables the "x" is replaced by an index (1 or greater) to address a value
from the table.
Name
OID
Type
Acc.
Description
epc1292TrapCtrl
.50.1.1.1.1.0
Integer32
RW
0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3
epc1292TrapIPIndex
.50.1.1.1.2.1.1.x
Integer32
RO
A unique value, greater than zero, for each receiver slot.
epc1292TrapAddr
.50.1.1.1.2.1.2.x
OCTETS
RW
DNS name or IP address specifying one Trap receiver slot. A port can
optionally be specified: 'name:port' An empty string disables this slot.
epc1292portNumber
.50.1.3.1.1.0
Integer32
RO
The number of Relay Ports
epc1292PortIndex
.50.1.3.1.2.1.1.x
Integer32
RO
A unique value, greater than zero, for each Relay Port.
epc1292PortName
.50.1.3.1.2.1.2.x
OCTETS
RW
A textual string containing name of a Relay Port.
epc1292PortState
.50.1.3.1.2.1.3.x
INTEGER
RW
current state of a Relay Port
epc1292PortSwitchCount
.50.1.3.1.2.1.4.x
Integer32
RO
The total number of switch actions ocurred on a Relay Port. Does not
count switch commands which will not switch the ralay state, so just real
relay switches are displayed here.
epc1292PortStartupMode
.50.1.3.1.2.1.5.x
INTEGER
RW
set Mode of startup sequence (off, on , remember last state)
epc1292PortStartupDelay
.50.1.3.1.2.1.6.x
Integer32
RW
Delay in sec for startup action
epc1292PortRepowerTime
.50.1.3.1.2.1.7.x
Integer32
RW
Delay in sec for repower port after switching off
epc1292ActivePowerChan
.50.1.5.1.1.0
Unsigned32
RO
Number of suppported Power Channels.
epc1292PowerIndex
.50.1.5.1.2.1.1.x
Integer32
RO
Index of Power Channel entries
epc1292ChanStatus
.50.1.5.1.2.1.2.x
Integer32
RO
0 = data not active, 1 = data valid
epc1292AbsEnergyActive
.50.1.5.1.2.1.3.x
Gauge32
RO
Absolute Active Energy counter.
epc1292PowerActive
.50.1.5.1.2.1.4.x
Integer32
RO
Active Power
epc1292Current
.50.1.5.1.2.1.5.x
Gauge32
RO
Actual Curent on Power Channel.