16
GB
Résolution d’une panne
Defect
Causes
Measure
Compressor not starting after
being switched on
Pressure in the air jet exceeds the
closing pressure
Release the pressure in the air jet
so that the pressure switch gets
automatically switched on
Defective supply
Have the current supply checked by
an authorised person
Defective pressure switch
Have the pressure switch replaced
by an authorised person (Güde
service centre)
Worn carbons
Replace the carbons
After reaching the closed pressu-
re, the compressor runs or buzzes
for a short time and then switches
off automatically
Electric cable is too long or its cross
section is too small
Check the length and cross section
of the electric cable
Compressor running constantly
Suction filter is very dirty
Clean or replace the suction filter
Pneumatic tools have high air
consumption
Check the pneumatic tool air
consumption;
seek an authorised compressed air
dealer
Leaking on the compressor
Localise the leaking, contact the
Güde service centre
Compressed-air pipeline leaking
Contact the Güde service centre
Drain valve is open or missing
Close or insert the drain valve
Compressor gets started too often Too much condensate in the air jet Drain the condensate
Compressor is overloaded
Safety valve blowing off
Pressure in the air jet exceeds the
set cut-off pressure
Have the pressure switch adjusted/
replaced by an authorised person
(Güde service centre)
Safety valve is defective
Replace the safety valve or contact
the Güde service centre
Compressor getting warm too
much
Air supply is not sufficient
Make sure sufficient air supply and
outlet (minimum distance from wall
is 40 cm) is provided
Cooling fins on the cylinder (cylin-
der head) are dirty
Clean the cooling fins on the cylin-
der (cylinder head)
Durée d’utilisation trop longue
Switch the compressor off
Compressor being overheated
and keeps switching off
Compressor is overloaded
Contact the Güde service centre
Compressor is defective
Contact the Güde service centre
Compressor under undervoltage
Contact the Güde service centre
Outdoor temperature of 35°C
ENGLISH
Содержание 50093
Страница 62: ...58 BG black out 4 S3 25 2 5 7 5 BetrSichV 17 25...
Страница 63: ...59 BG www guede com 12 24 www guede com 16 DIN 13164 1 2 3 4...
Страница 65: ...61 BG nl turare defec iune G de G de G de G de G de 40 Perioad de utilizare prea lung G de G de G de 35 C...
Страница 81: ......
Страница 82: ......
Страница 83: ......