61
Expert PDU Energy 8340/8341
© 2021 GUDE Systems GmbH
Specifications
ethernet phyprefer set {10MBIT_HD=0|
10MBIT_FD=1|100MBIT_HD=2|100MBIT_FD=3}
sets preferred speed for PHY Auto Negotiation
ethernet phyprefer show
shows preferred speed for PHY Auto Negotiation
extsensor
enters cmd group "extsensor"
extsensor all show
shows all values from connected external sensors
extsensor all show
shows all plugged sensors and fields
extsensor {port_num} {sen_field} value show
shows sensor value
6
extsensor {port_num} {sen_type} label set
"{name}"
sets sensor name to label
6
extsensor {port_num} {sen_type} label show
shows label of sensor
6
extsensor {port_num} type show
shows type of sensor
extsensor {port_num} {sen_type} {sen_field}
events set {off=0|on=1}
enables sensor events on/off
6
extsensor {port_num} {sen_type} {sen_field}
events show
shows if sensor events are enabled
6
extsensor {port_num} {sen_type} {sen_field}
events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2
,EVT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER
=5,EVT_DISPLAY=6,EVT_CONSOLE=7,EVT_M
QTT=8}"
enables different event types
6
extsensor {port_num} {sen_type} {sen_field}
events type show
shows what event types are enabled
6
extsensor {port_num} {sen_type} {sen_field}
events beeper mode set {CONTINOUS=0|
INTERMITTENT=1}
sets beeper tone
extsensor {port_num} {sen_type} {sen_field}
events beeper mode show
shows beeper tone
extsensor {port_num} {sen_type} {sen_field}
maxval set {num}
sets maximum value for sensor
6
extsensor {port_num} {sen_type} {sen_field}
maxval show
shows maximum value for sensor
6
extsensor {port_num} {sen_type} {sen_field}
minval set {num}
sets minimum value for sensor
6
extsensor {port_num} {sen_type} {sen_field}
minval show
shows minimum value for sensor
6
extsensor {port_num} {sen_type} {sen_field} hyst
set {num}
sets hysterese value for sensor
6
extsensor {port_num} {sen_type} {sen_field} hyst
show
shows hysterese value for sensor
6
extsensor {port_num} {sen_type} {sen_field}
publish mode set {NONE=0|INTERVAL=1|
DELTA=2|INTERV_DELTA=3}
sets publish mode
extsensor {port_num} {sen_type} {sen_field}
publish mode show
shows publish mode
extsensor {port_num} {sen_type} {sen_field}
publish mqtt retain set {OFF=0|ON=1}
sets mqtt retain
extsensor {port_num} {sen_type} {sen_field}
publish mqtt retain show
shows if mqtt retain set
extsensor {port_num} {sen_type} {sen_field}
publish timer set {num_secs}
sets publish time interval
extsensor {port_num} {sen_type} {sen_field}
publish timer show
shows publish time interval
extsensor {port_num} {sen_type} {sen_field}
publish delta set {float}
sets publish delta value
extsensor {port_num} {sen_type} {sen_field}
publish delta show
shows publish delta value
extsensor period set {24H=0|12H=1|2H=2|1H=3|
30MIN=4}
sets sensor Min/Max measurement period
extsensor period show
shows sensor Min/Max measurement period
extsensor beeper set {OFF=0|ON=1}
enables beeper sensor alarms
extsensor beeper show
shows if beeper sensor alarms are enabled
http
enters cmd group "http"
http server set {HTTP_BOTH=0|HTTPS_ONLY=1|
HTTP_ONLY=22|HTTPS_REDIR=3}
sets accepted connection types
http server show
shows accepted connection types
http port set {ip_port}
sets http port
http port show
shows http port
http portssl set {ip_port}
sets https port
http portssl show
shows https port
http tls mode set {TLS12=0|TLS13_12=1|
TLS13=2|TLS13_12_11=3}
restricts TLS mode
http tls mode show
shows TLS mode restriction
http ajax enabled set {OFF=0|ON=1}
enables ajax autorefresh on/off
http ajax enabled show
shows if ajax autorefresh enabled
Содержание Expert PDU Energy 8340 Series
Страница 2: ...2 Expert PDU Energy 8340 8341 2021 GUDE Systems GmbH...
Страница 5: ...Device Description...
Страница 12: ...12 Expert PDU Energy 8340 8341 2021 GUDE Systems GmbH Device Description...
Страница 13: ...Operating...
Страница 21: ...Configuration...
Страница 43: ...Specifications...
Страница 76: ...Support...
Страница 81: ...81 Expert PDU Energy 8340 8341 2021 GUDE Systems GmbH Index Timer 33 Timer Configuration 33 TLS 53...