background image

 G

uar

di

an

 F

al

l P

ro

te

ct

io

 63

05

 S

. 2

31

st 

St

., 

Ken

t, 

W

A

 9

80

32 

 

3

Installation and Use

Requirements for guardrail systems:

MAXIMUM permitted roof pitch is 1/12 (5°).

Toprails must be 42” (+/- 3”) above the work surface or, if used in stilt work applications, 42” plus the height
of stilts.

Midrails must be installed halfway between the top edge of the guardrail system and the working level (not
the toeboard).

All intermediary rails (not the toprail or the midrail) must not allow for gaps greater than 19”.

Toeboards are REQUIRED on roofs of slopes more than 4/12 (vertical/horizontal).

Toeboards are REQUIRED if a risk exists for tools, equipment, materials, or other substances to fall down to a
lower level.

Toeboards must be a minimum 3½” from their top edge to the working surface, and must not have greater
than ¼” clearance between their bottom edge and the work surface.

Содержание G-Rail

Страница 1: ...ctions Read and understand these instructions before using equipment Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Safety Information 6 Product Specific Applications 2 Componen...

Страница 2: ...d associated components Worker Classifications CAUTION Understand the following definitions of those who work near or who may be exposed to fall hazards Qualified Person A person with an accredited de...

Страница 3: ...any connections to guardrail systems WARNING NEVER lean or climb on guardrail systems WARNING Fall Prevention G Rails may be used in Fall Prevention applications ONLY Fall Prevention Systems are plac...

Страница 4: ...ge of the guardrail system and the working level not the toeboard All intermediary rails not the toprail or the midrail must not allow for gaps greater than 19 Toeboards are REQUIRED on roofs of slope...

Страница 5: ...YS use outriggers at BOTH ends of any interruption in continuous guardrail sections and at BOTH ends of a continuous guardrail section An outrigger is a guardrail installed perpendicular to a continuo...

Страница 6: ...king and hazardous materials Ensure that selected work area will support the application specific minimum loads set forth in this instruction manual Work area MUST be stable At least every 6 months a...

Страница 7: ...st falls within 24 Class B SRLs must arrest falls within 54 Harnesses and connectors selected must be compliant with manufacturer s instructions and must be of compatible size and configuration Snap h...