9. LOW BATTERY ALERT
10. GUARDIAN OVERRIDE
11. SWITCHING OFF THE GUARDIAN
12. OPERATING WITHOUT OLAS TRANSMITTING DEVICES
13. RECOMMENDATIONS
•
A low battery alert will be initiated by the Guardian when an OLAS Tag’s battery level goes below 20%
•
The alert is indicated by a red flash every 10 seconds on the control switch and the Guardian Hub
•
The alert will remain until the battery is changed
•
You can check which OLAS tag has low battery using the OLAS app
Once you have located the tag you can
either:
1.
Pause the Guardian, change the battery and restart tracking
2.
Or
switch off the Guardian to remove the OLAS tag from the log, switch off the OLAS tag and restart
the Guardian
•
The Guardian can be switched off at any point by pressing the control switch for 4 seconds
•
The control switch will illuminate red with a sound signal before switching off
•
When switched ON the Guardian will automatically scan for OLAS transmitters
•
If no transmitters are found the Guardian will emit an alert sound every second
•
To override the Guardian, press the control switch for 4 seconds which will switch the Guardian off,
your vessel will now operate normally.
•
Switch off your OLAS transmitter if it is not going to be used for longer than 24 hours
•
Check the battery life of the OLAS tags in the OLAS mobile application before you leave
•
Check your OLAS Float-On’s battery status before your journey and charge if required
WARNING:
the cut-off switch and alarm will not operate!
ALWAYS WEAR A TRADITIONAL KILL CORD
•
When an OLAS transmitter goes out of range an alert will sound, the control switch will flash red and
as a default setting the engine will cut-off
•
After 5 seconds the engine can be started again so a rescue can be performed
•
Press the control switch once to stop the alarm and pause the tracking
•
Once the OLAS transmitter is back on the vessel and within 1 metre of the control switch, press the
control switch once and tracking will continue
•
LIMITATIONS
The connection signal can be blocked by carbon and metal. Operation on carbon or metal boats will require
the Guardian box to be mounted externally.
SOUND AND LIGHT INDICATIONS
OPERATION
ACTION/REACTION
DURATION
Turning ON
Control switch - Green
2 seconds
Box – Low red
Buzzer ON
No OLAS transmitters in range
Control switch – Red
Pulsing 0.5 seconds
ON/OFF
Box – Low red
Buzzer ON
Initial scan for OLAS transmitters within 1 metre
Control switch – Green
Pulsing 1 second ON/OFF for 30
seconds
Box – Low red
Indication of logged OLAS transmitters
Control switch – Green
Pulsing 0.5 seconds ON/OFF, 1 pulse
per transmitter up to max 15
Box – Low red
Buzzer ON
Tracking OLAS transmitters
Control switch – Green
Continuous
MOB Alert
Control switch - Red
Continuous lights
Pulsing buzzer
Box – High red
Buzzer ON
Tracking paused
Control switch – Green
Pulsing 3 second ON/OFF
Buzzer once every 6 seconds
Box – Low red
Buzzer ON
Scanning and logging transmitters within 1 metre
Control switch – Green
Pulsing 1 second ON/OFF
Box – Low red
Low battery alert for OLAS tag
NOTE: OLAS Float-On does not transmit battery status
Control switch – Red
Pulsing once every
10 seconds
Box – Low red LED
SPECIFICATION
Power/Current
10-32V/13~17mA
Vessel length
50ft
Connected Transmitters
up to 15
Weight
110 grams
Size
92 x 90 x 38 mm
LED output
55lm
Buzzer output
85db
Pause will remain active if the OLAS transmitter that was lost is not back within 1 metre of