![Guardian 55 ES Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/guardian/55-es/55-es_operators-manual_2276921021.webp)
21
COMPRESSOR LUBRICATION
A clear sight gauge or window is located on the air compressor indicating lubrication oil
level. Ensure the oil level is maintained to 2/3 full as visible on the sight gage. Use 30
weight, non-detergent oil for temperatures above 56°F, or 20 weight non-detergent oil
for temperatures from 32-55°F. Temperatures below 32°F are not recommended for
atomization.
CLEANING THE MACHINE
•
Keeping this ULV machine clean is paramount in maintaining a well running and efficient
ULV sprayer.
•
Washing this machine after each use is highly recommended.
•
Use warm water and general duty cleaners.
Pressure washing is not recommended!
•
DO NOT spray electrical components directly.
BELT TENSION
Correct belt tension and alignment is essential for proper operation and longevity of this ULV
sprayer. When adjusting the belt tension, ensure the alignment is maintained when the
fasteners are loosened and retightened after adjustment. Use a straight edge across the face of
the Compressor flywheel and align the engine’s pulley face with it before securing the engine
mounting bolts.
An over-tightened drive belt can cause excessive pulley wear, shorten the belt’s life and place
too much strain on bearing surfaces of the devices being driven. Conversely, a belt too loose
allows slippage and under performance of the machine. The best method for setting the
proper tension is the “Deflection” method. A good rule of thumb is 1/64” of deflection for
every inch between the pulley centers.