background image

Introduction

Thank you for purchasing a Guardian Fall 
Protection Metal Energy Absorber. This 
manual must be read and understood in its 
entirety, and used as part of an employee 
training program as required by OSHA or any 
applicable state agency.

This and any other included instructions
must be made available to the user of the
equipment. The user must understand how
to safely and effectively use the Metal 
Energy Absorber, and all fall safety 
equipment used in combination with the 
Metal Energy Absorber.

User Information

Date of First Use:

Serial #:

Trainer:

User:

Applicable Safety Standards

When used according to instruction specifications, this product meets or exceeds all applicable OSHA 1926
Subpart M and OSHA 1910 standards for fall protection. Applicable standards and regulations depend on 
the type of work being done, and also might include state-specific regulations. Consult regulatory 
agencies for more information on fall protection systems and associated components.

Worker Classifications

!

CAUTION

Understand the following definitions of those who
work near or who may be exposed to fall hazards.

Qualified Person:

 A person with an accredited degree or certification, and with extensive experience or

sufficient professional standing, who is considered proficient in planning and reviewing the conformity of fall
protection and rescue systems.

Competent Person:

 A highly trained and experienced person who is ASSIGNED BY THE EMPLOYER to be

responsible for all elements of a fall safety program, including, but not limited to, its regulation, management,
and application. A person who is proficient in identifying existing and predictable fall hazards, and who has
the authority to stop work in order to eliminate hazards.

Authorized Person:

 A person who is assigned by their employer to work around or be subject to potential or

existing fall hazards.

It is the responsibility of a Qualified or Competent person to supervise the job site and ensure all
applicable safety regulations are complied with.

   

G

ua

rd

ia

Fa

ll 

Pr

ot

ec

tio

  6

30

S.

 2

31

st

 S

t.

, K

en

t,

 W

A

 9

80

32

   

   

 p

ho

ne

: (

80

0)

 4

66

-6

38

 f

ax

: (

80

0)

 6

70

-7

89

   

  w

w

w

.g

ua

rd

ia

nf

al

l.c

om

1

Содержание 15206

Страница 1: ...tions Read and understand these instructions before using equipment Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Safety Information 10 11 Product Specific Applications 2 Limitations 2 4 Components and Specifications 5 6 Maintenance Cleaning and Storage 9 Inspection 9 Installation and Use 6 9 Inspection Log 10 Labels 11 ...

Страница 2: ...ssociated components Worker Classifications CAUTION Understand the following definitions of those who work near or who may be exposed to fall hazards Qualified Person A person with an accredited degree or certification and with extensive experience or sufficient professional standing who is considered proficient in planning and reviewing the conformity of fall protection and rescue systems Compete...

Страница 3: ...tical horizontal Applicable D rings Dorsal Chest Side Shoulder WARNING Use of equipment in unintended applications may result in serious injury or death Maximum 1 attachment per connection point For all applications worker weight capacity range including all clothing tools and equipment is 130 420 lbs Limitations Fall Clearance There must be sufficient clearance below the anchorage connector to ar...

Страница 4: ...ng Roof Edge Either Direction X Working Angle From Perpendicular Ø 6 10 15 20 25 30 35 40 45 50 55 60 8 9 9 11 7 13 3 14 6 16 17 2 18 3 19 4 19 10 21 4 22 3 53 45 38 33 30 28 26 24 23 21 21 21 For example if the anchorage connector is 6 from the leading edge Y the working distance X is 8 in each direction from the perpendicular which translates to a 53 working angle Swing Falls Prior to installati...

Страница 5: ...6 6385 fax 800 670 7892 www guardianfall com 4 SAFE ATTACHMENT ZONE DANGER ZONE WORK IN THIS AREA NOT ALLOWED Horizontal Lifeline 100 120 60 SAFE ATTACHMENT ZONE EXTENDS FOR ENTIRE BUILDING ROOF PERIMETER Horizontal Lifeline 120 PLACE HLL 6 10 BACK FROM LEADING EDGE 60 ...

Страница 6: ...ips 2 CB 1 W Anchors 2 2 5 O rings Metal Energy Absorber System for Column Ceiling Mount Applications Over 60 Includes 2 Energy Absorbers 3 Shackles 2 Thimbles 1 Turnbuckle 6 Fist Grips 2 CB 1 B Anchors 2 2 5 O rings Metal Energy Absorber System for Column Ceiling Mount Applications Over 60 Includes 2 Energy Absorber 3 Shackles 2 Thimbles 1 Turnbuckle 6 Fist Grips 2 6 Premium Cross Arm Straps 2 2 ...

Страница 7: ...d by this instruction manual NEVER over tighten cable Proper sag in cable reduces forces of Fall Arrest 6 If performing installation at heights over 6 ALWAYS use a complete and independent PFAS until Metal Energy Absorber HLL System is fully installed and able to withstand forces of Fall Arrest as specified by this instruction manual Always maintain 100 tie off Guardian recommends using 3 8 diamet...

Страница 8: ...n until at least 1 full thread is visible 7 Place wire rope thimble on other end of turnbuckle Tighten bolt until at least 1 full thread is visible Attach second steel shackle and thimble to anchor point or Metal Energy Absorber at opposite end of system second turnbuckle is not used Slack 6 Tightening bolts on the Absorbinator system YES NO 3 Attach Metal Energy Absorber to anchor point using pro...

Страница 9: ...7 Class IPS XIP or XXIP sizes 1 and smaller For other classes of wire rope not mentioned above we recommend contacting Crosby Engineering to ensure the desired efficiency rating The style of wire rope termination used for any application is the obligation of the user 1 Refer to Table 1 in following these instructions Turn back specified amount of rope from thimble or loop Apply first clip one base...

Страница 10: ... all dirt corrosives and contaminants from Metal Energy Absorber before and after each use If Metal Energy Absorber cannot be cleaned with plain water use mild soap and water then rinse and wipe dry NEVER clean Metal Energy Absorber with corrosive substances When not in use store equipment where it will not be affected by heat light excessive moisture chemicals or other degrading elements Prior to...

Страница 11: ...not misuse equipment Workplace conditions including but not limited to flame corrosive chemicals electrical shock sharp objects machinery abrasive substances weather conditions and uneven surfaces must be assessed by a Competent Person before fall protection equipment is selected The analysis of the workplace must anticipate where workers will be performing their duties the routes they will take t...

Страница 12: ... Equipment subjected to forces of fall arrest must immediately be removed from use Age fitness and health conditions can seriously affect the worker should a fall occur Consult a doctor if there is any reason to doubt a user s ability to withstand and safely absorb fall arrest forces or perform set up of equipment Pregnant women and minors must not use this equipment Physical harm may still occur ...

Отзывы: