Guardian 15176 Скачать руководство пользователя страница 3

Product Specific Applications

Personal Fall Arrest:

 Window Gap Anchor may be used to support a MAXIMUM 1 PFAS for use in

Fall Arrest applications. Structure must withstand loads applied in the directions permitted by the
system of at least 5,000 lbs. Maximum free fall is 6‘, or up to 12’ if used in combination with
equipment explicitly certified for such use. Applicable D-ring: Dorsal.

Restraint:

 Window Gap Anchor may be used in Restraint applications. Restraint systems prevent

workers from reaching the leading edge of a fall hazard. Always account for fully deployed length
of lanyard/SRL. Structure must withstand loads applied in the directions permitted by the system
of at least 1,000 lbs. No free fall is permitted. Restraint systems may only be used on surfaces
with slopes up to 4/12 (vertical/horizontal). Applicable D-rings: Dorsal, Chest, Side, Shoulder.

!

WARNING

Use of equipment in unintended applications may result in serious

injury or death. Maximum 1 attachment per connection point.

For all applications: worker weight capacity range

(including all clothing, tools, and equipment) is 130-420 lbs.

Limitations

Fall Clearance:

 There must be sufficient

clearance below the anchorage connector
to arrest a fall before the user strikes the
ground or an obstruction. When calculating
fall clearance, account for a MINIMUM 2’
safety factor, deceleration distance, user
height, length of lanyard/SRL, harness
stretch, and all other applicable factors.

Diagram shown is an example fall
clearance calculation ONLY.

Swing Falls:

 Prior to installation or use,

make considerations for eliminating or
minimizing all swing fall hazards. Swing
falls occur when the anchor is not directly
above the location where a fall occurs.
Always work as close to in line with the
anchor point as possible. Swing falls
significantly increase the likelihood of
serious injury or death in the event of
a fall.

   

G

ua

rd

ia

Fa

ll 

Pr

ot

ec

tio

  6

30

S.

 2

31

st

 S

t.

, K

en

t,

 W

A

 9

80

32

   

   

 p

ho

ne

: (

80

0)

 4

66

-6

38

 f

ax

: (

80

0)

 6

70

-7

89

   

  w

w

w

.g

ua

rd

ia

nf

al

l.c

om

2

Fall clearance calculation shown based on standing

worker falling directly in-line with anchor point.

Always consider potential swing fall and other

hazards when calculating fall clearance.

*Eliminate Swing Fall whenever

possible! If Swing Fall exists,

always account for additional

fall clearance.

1.5’

2’

12’

5’

Anchor Point

at Foot Level

12’ Free Fall 

Lanyard

Anchor Point

Level w/Dorsal D-ring

6’ Free Fall 

Lanyard

2’

Содержание 15176

Страница 1: ...and these instructions before using equipment Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Safety Information 6 Product Specific Applications 2 Limitations 2 3 Components and...

Страница 2: ...nts Worker Classifications CAUTION Understand the following definitions of those who work near or who may be exposed to fall hazards Qualified Person A person with an accredited degree or certificatio...

Страница 3: ...bs Limitations Fall Clearance There must be sufficient clearance below the anchorage connector to arrest a fall before the user strikes the ground or an obstruction When calculating fall clearance acc...

Страница 4: ...l Protection 6305 S 231st St Kent WA 98032 phone 800 466 6385 fax 800 670 7892 www guardianfall com 3 Compatibility When making connections with Window Gap Anchor eliminate all possibility of roll out...

Страница 5: ...it is installed as prescribed Do not use in horizontal lifeline HLL applications Installation 1 Remove Clevis Pin from Telescoping Bar adjust Window Gap Anchor to fit into frame and reinsert Clevis P...

Страница 6: ...ts or damage are found or if exposed to forces of fall arrest Ensure that applicable work area is free of all damage including but not limited to debris rot rust decay cracking and hazardous materials...

Страница 7: ...E SRLs Class A SRLs must arrest falls within 24 Class B SRLs must arrest falls within 54 Harnesses and connectors selected must be compliant with manufacturer s instructions and must be of compatible...

Страница 8: ...EMOVE FROM SERVICE DO NOT REMOVE LABELS YR MO WARNING 1 800 466 6385 www guardianfall com Window Gap Anchor Part 15176 Compliant with OSHA 1910 and OSHA 1926 Subpart M regulations Prior to use read an...

Отзывы: