Installing the HDE-11/1100-VoIP Telephones
Follow all appropriate electrical codes and use only approved electrical fittings for the
installation.
To Avoid The Danger Of An Accidental Shock or Circuit Damage
o
If using an auxiliary power supply ensure that it is unplugged during installation.
o
If using the onboard relay to control an external device or relay ensure power is off during
installation.
Determine if power to operate the telephone will be provided via the ethernet or if external
power will be required. If external power is required install Guardian’s Auxiliary Power Supply
or equivalent.
Remove the cover screws from the front of the unit and carefully remove the front cover
assembly. Note that the electronics are attached to the front plate
Prepare an opening 7
5
/
8
" (193 mm) wide, 10 ¼” (260 mm) high and 2 ½" (64 mm) deep.
Install blocking around the rough opening if required.
See: Figure 5 - HDE-11-
VoIP & HDE-1100-VoIP
Mounting
Trim the left and right edges of the opening so that the upper surface of the enclosure flanges
will be flush with the exterior of the wall when it is installed.
Install a cable gland or bushing into the 7/8” (22mm) opening in the bottom of the enclosure
for the network cable.
If additional access is required for auxiliary power or connection to the on board relay punch
another opening in the bottom of the enclosure near the original opening. Make sure that the
fittings or wiring will not interfere with the PCBA or any parts of the faceplate when it is
installed.
Thread the bare end of the Network cable out of the enclosure through the gland and opening.
If using an alternate power supply bring the wiring through the opening and into the enclosure.
If the onboard relay is to be utilized bring the wiring through the opening and into the
enclosure.
Secure the enclosure into the opening with flat head screws.
To facilitate making connections the faceplate can be temporarily attached inverted to either
side of the enclosure.
Insert the Network plug into the RJ-45 connector on the PCBA.
Connect the alternate power supply to the terminal block if it is used.
See: Figure 9 - Terminal
Block Connections and
Section 12.2
a Device to the Auxiliary
Relay
Connect the onboard relay wiring to the terminal block if it is used.
Commissioning
Turn on the auxiliary power supply if utilized.
Connect the telephone into the network. Allow approx. 30sec for the phone to boot up.
Determine that the telephone is properly connected by pressing the RTFM switch for less than
five seconds to announce the IP address.
Test the unit by calling to and from another unit.
Test the operation of the on board relay if it is utilized.
Ensure all connections are tight, then replace and secure the faceplate. Use the driver bit
provided to install the tamper resistant screws.
Tip: Store the driver bit in a
secure place for future use.
Programming
Set up and configure if changes are required to the default settings.
Tip: See Manual P007402
- Setup and Configuration
Test the unit by making calls to and from another unit.