Restraint:

 Rope Anchor may be used in Restraint applications. Restraint systems prevent workers

from reaching the leading edge of a fall hazard. Always account for fully deployed length of
lanyard/SRL. Structure must withstand loads applied in the directions permitted by the system of
at least 1,000 lbs. No free fall is permitted. Restraint systems may only be used on surfaces with
slopes up to 4/12 (vertical/horizontal). Applicable D-rings: Dorsal, Chest, Side, Shoulder.

For all applications: worker weight capacity range

(including all clothing, tools, and equipment) is 130-420 lbs.

FALL CLEARANCE CALCULATION

Lanyard length

(6’ total)

Safety factor

(3’ total)

Deceleration

distance (4’ total)

Height of harness

dorsal D-ring from

worker’s feet

(6’ total)

Required

distance

from

anchorage

(19’ total)

Limitations

Compatibility:

 When making connections with Rope Anchor, eliminate all possibility of roll-out. Roll-out

occurs when interference between a hook and the attachment point causes the hook gate to unintentionally
open and release. All connections must be selected and deemed compatible with Rope Anchor by a
Competent Person. All connector gates must be self-closing and self-locking, and withstand minimum loads of
3,600 lbs. See the following for examples of compatible/incompatible connections:

Fall Clearance:

 There must be sufficient

clearance below the anchorage connector
to arrest a fall before the user strikes the
ground or an obstruction. When calculating
fall clearance, account for a MINIMUM 3’
safety factor, deceleration distance, user
height, length of lanyard/SRL, and all other
applicable factors.

Diagram shown is an example fall
clearance calculation ONLY.

Swing Falls:

 Prior to installation or use, make

considerations for eliminating or minimizing
all swing fall hazards. Swing falls occur when
the anchor is not directly above the location
where a fall occurs. Always work as close to in
line with the anchor point as possible. Swing
falls significantly increase the likelihood of
serious injury or death in the event of a fall.

Connector
closed and
locked to
D-ring. 

OK.

Connector
to integral
lanyard.

NO.

Two connectors
to same
D-ring. 

NO.

Connector
directly to
webbing.

NO.

 

Содержание 01300

Страница 1: ...these instructions before using equipment Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Safety Information 6 Product Specific Applications 1 2 Limitations 2 3 Components and Specifications 3 Maintenance Cleaning and Storage 5 Inspection 5 Installation and Use 3 4 Inspection Log 5 Labels 7 ...

Страница 2: ...son A person with an accredited degree or certification and with extensive experience or sufficient professional standing who is considered proficient in planning and reviewing the conformity of fall protection and rescue systems Competent Person A highly trained and experienced person who is ASSIGNED BY THE EMPLOYER to be responsible for all elements of a fall safety program including but not lim...

Страница 3: ...he hook gate to unintentionally open and release All connections must be selected and deemed compatible with Rope Anchor by a Competent Person All connector gates must be self closing and self locking and withstand minimum loads of 3 600 lbs See the following for examples of compatible incompatible connections Fall Clearance There must be sufficient clearance below the anchorage connector to arres...

Страница 4: ...sharp or abrasive edges and surfaces and hazardous materials 4 Rope Anchor MUST be used with rope 5 8 3 4 in diameter only Installation Rope Anchor may be connected to a compatible vertical lifeline VLL or rope lanyard in two different fashions 1 Compatible rope may be threaded through holes 1 5 and tied off at hole 5 Hole 6 may then function as an anchorage connector 2 Compatible rope may be thre...

Страница 5: ...orm a knot Ensure there is no rope slack over entire length of Rope Anchor Rope Threading 2 1 Repeat process for Rope Threading 1 DO NOT make any connections to hole 6 2 Secure long end of selected rope over a compatible anchor point Anchor point MUST NOT consist of any sharp or abrasive surfaces or edges 3 Thread long end of selected rope through hole 6 and pull through so the Rope Anchor and rop...

Страница 6: ... all damage including but not limited to debris rot rust decay cracking and hazardous materials Ensure that selected work area will support the application specific minimum loads set forth in this instruction manual Work area MUST be stable At least every 6 months a Competent Person other than the user must inspect Rope Anchor Competent Person inspections MUST be recorded in inspection log in inst...

Страница 7: ...n 24 Class B SRLs must arrest falls within 54 Harnesses and connectors selected must be compliant with manufacturer s instructions and must be of compatible size and configuration Snap hooks carabiners and other connectors must be selected and applied in a compatible fashion All risk of disengagement must be eliminated All snap hooks and carabiners must be self locking and self closing and must ne...

Страница 8: ...on back of Anchor ROPE ANCHOR MADE IN TAIWAN P N 01300 USE 5 8 3 4 16 19 mm OR APPROVED ROPE ONLY WARNING READ AND FOLLOW MFG S INSTRUCTIONS Distributed by Engineered Fall Protection Sales EngineeredFallProtection com 314 492 4422 www EngineeredFallProtection com ...

Отзывы: