2. Initial Installation

The Guardall V12 is designed to tolerate a wide
range of environments, however, the normal
professional installation guidelines should be
followed:

a)  Avoid the main false alarm sources:

* Sunlight shining directly onto the detector,
* Heat sources within a zone,
* Strong air draughts onto the detector.
Mount the detector on a stable surface which
is not subject to vibration. Large objects placed
in front of the detector will cause significant
changes in coverage.

b)  Preparation & Mounting

-

Loosen the cover screw and remove the front
cover.

-

Grip the PCB at the connector block and pull
forward while easing the retaining clips apart.
Lift the module clear from the clips on the rear
moulding.

-

Decide on the mounting position and cable
routing. The recommended mounting height
is 2.3 m (7ft 6in).

-

Push out cable entry and appropriate mounting
hole knock-outs (A for corner, B for flush
mounting).

-

Fit the rear moulding to the wall.

Guardall Limited

Lochend Industrial Estate

Newbridge

Edinburgh EH28 8PL

Technical Hotline: 0131-333-3802

Website: www.guardall.co.uk

Part No. 320683-0B

c)  Wiring

-

Run cables through the cable entry hole.

-

Holding the connector block, fit the PCB into
the rear moulding by inserting it into the lower
retaining clips and clicking firmly into position.

-

Connect the wires to the PCB terminal block.

-

Guardall standard EOL resistors (8K2) can be
enabled by setting switches 5 and 6 ON. For
NEOL applications or operations with other
resistor values, keep switch 5 and 6 OFF.
Connect EOL loop between terminals 3 and 7
of the connector block.

-

Do not re-fit the front cover at this stage.

3. Pulse Count

In potentially troublesome environments the
chance of false alarms can be further reduced
by enabling Pulse Count (switch 2 ON). The first
detection will then only cause a short LED flash
(if enabled, see section 5b). A second detection
within 25 seconds is required to generate a unit
alarm. With Pulse Count disabled (switch 2 OFF)
all detections will generate a unit alarm.

4.  PIR Gain

The Guardall V12 is set for a detection area of 10
x 10m. To decrease the range to 7 x 7m BOTH
switches 3 and 4 must be moved to the 7m
setting. The normal coverage instructions should
also be followed (see section 5).

5. Checking V12 Coverage

Note that there will be a short delay (less than 1
second) between movement and a unit alarm
being generated while the Guardall V12 verifies
the intruder signature.

To verify coverage:

a) Ensure that the voltage at terminals 1 and 2 is

between 9 V and 16 V dc.

b)  Enable the LED by ensuring switch 1 is set ON

(as supplied) or by taking the Test Input high.

c) The horizontal coverage can be adjusted when

corner mounted by loosening the wall
mounting screws and adjusting the unit as
required.
Note: the lens position has been factory set for
optimum Pet tolerant operation and so should
not require vertical adjustment.

d) Walk test the protected area checking that

alarms are indicated at the control panel.

e) Finally fit the front cover and tighten the cover

screw.

HS Connections with internal

resistors selected

Connector
Block

Detector

7

3

Alarm

Tamper

8k2

8k2

1. Technical Specification

Detector Voltage :

9 V to 16 V dc.

Current :

12 mA non-alarm, 11 mA
alarm, typical at 12 V dc.

Max Ripple :

2 V peak to peak at
12 V dc.

PIR Coverage

±

5

°

 horizontally when

Adjustment :

corner mounted.

LED Indication :

Internal switch or Test
Input to enable.

Temperature Range : -10

°

C to +55

°

C (14

°

F to

130

°

F).

Temperature

Increases gain only when

compensation :

room temperature close to
body temperature.

Alarm Output :

Normally closed, voltage

(NC ALARM)

free, reed relay contacts.
Rated at 24 V dc, 50 mA
with a maximum 10 Ohm
on resistance.

Alarm Period :

Approximately 3  seconds.

Tamper Output:

Normally closed, voltage

(NC TAMPER)

voltage free, switch
contacts. Rated at
30 V dc, 50 mA.

Test Input (TEST):

Normally low or open
circuit, connect to
detector's positive
supply to activate (High).
Must have common
ground with detector.

Pet Friendly Series

The Pet Friendly V12 operates on the
basis of masking the lower beams while
slightly declining the remaining beams.
This allows pets to move around
domestic applications at ground level
freely without causing an alarm
condition, provided that the installation
guidelines are followed.

It is advised that pets are allowed to
climb on furniture for walk testing
purposes. If this causes the unit to
alarm, it is suggested that the lens is
moved towards position A.

6. Diagnostics

Periodic self test
The detector regularly performs an internal
electrical self test. If the self test detects a failure,
the LED will illuminate dimly within approximately
an hour. This condition will be reset by either a
unit alarm or a successful periodic self test.

Supply voltage monitor
The supply is continuously monitored. If it falls
significantly below 9 Volts, the LED will  flash at
1Hz (once / second) between bright and dimly
illuminated. This condition will be reset if the
supply voltage returns to greater than 9V dc.

7. LED Indications

Low Voltage

Flashing slow (1 Hz = once
/ sec) between bright and
dimly illuminated.

Alarm

On for 3 seconds if LED
enabled.

Periodic self test fail

LED illuminated dimly

8. Troubleshooting

No LED indication

Check LED Enable is
selected, i.e. switch 1 ON
or Test Input high.

LED flashing slowly

Check supply voltage is

bright/dim

greater than 9 V dc.

LED illuminated

Periodic self test fail; check

dimly

unit operation.

Continuous PIR activity Check for strong draughts
indicated by LED

and other known constant

activity

alarm sources.

Poor detection

Check lens adjustment.

Any further queries can be directed to the Guardall
Technical Hotline: 0131 - 333 - 3802.

9. Warranty

All Guardall products are warranted against
defects in workmanship in materials (details
available on request). In the interests of improving
quality and design, Guardall reserve the right to
amend specifications without giving prior notice.
Faulty product should be returned to your supplier.

Coverage Diagrams

Side View Pet Friendly V12

2.3m

0.9m

Pet tolerant area

      0m                                                                                10m

Note: Detection may occur at ranges greate than 10m within
the Pet tolerant area.

0m                                     5m                                    10m

7.5m

0m

7.5m