Guangzhou Yingfeng Lighting Equipment Co.,Ltd
www.yf-light.com
8
11 channel description
:
9
、
Common problems and solutions
:
10
、
Maintenance and cleaning
★
This moving head must keep the basic cleaning, dust,dirty objects and smoke and oil residue cannot remain on of
inside of the shells.Otherwise is will significantly reduce the output of the moving head.A regular cleaning will not only
221-2
R255 G255 B118 W255
226-2
R255 G255 B132 W255
231-2
R255 G255 B151 W255
236-2
R255 G255 B171 W255
241-2
R255 G255 B185 W255
246-2
R255 G255 B197 W255
251-2
R255 G255 B234 W255
15
Reset
CH
value
Control function
1
0-255
Master dimming on
2
0-255
Red color dimming from dark to bright
3
0-255
Green color dimming from dark to bright
4
0-255
Blue color dimming from dark to bright
5
0-255
White color dimming from dark to bright
6
0-255
User defined color dimming from dark to bright
7
0-255
X axis motor
8
0-255
Y axis motor
9
0-255
X axis fine adjustment
(
16Bit
)
10
0-255
Y axis fine adjustment
(
16Bit
)
11
0-255
XY axis motor speed from fast to slow
Problems
Troubleshoot direction
Solutions
No response after the lamp powered,
no boot, the screen does not light up
Check if the power supply have correct
access, the fuse is burning
Access the power correctly , replace the fuse after
troubleshooting
Lamps not controllers by the console
Check if the signal have correct access, the
address have set correctly.
Access the signal correctly, set the address code
correctly
Master-slave control mode, some of
the lamp is not managed properly.
Check if the no controlled lamp is under
the console mode, if it have disconnected
from the console, if there have more than
one master device.
Set the lamp to console mode, disconnect the
console connection, turn off the other master
device.
If there are other problem that is not within the above please contact the dealer.