GTV, ul. Przejazdowa 21, 05-800 Pruszków; tel. 22 444 75 00; fax 22 444 75 01; www.gtv.com.pl
• Unload the cover directly.
• Connect the power and the load into the connection-wire column of the sensor according to connection-wire diagram.
• Fix the sensor on the selected position with the inflated screw as the figure on the right.
• Install back the cover and then you can test it.
CONNECTION-WIRE DIAGRAM:
(See the right figure)
TEST:
• Turn the TIME knob anti-clockwise on the minimum (10 s). Turn the LUX knob clockwise on the maximum (sun).
• Switch on the power; the sensor and its connected lamp will have no signal at the beginning. After Warm-up 30 sec,
the sensor can start work .If the sensor receives the induction signal, the lamp will turn on. While there is no another
induction signal any more, the load should stop working within 10 sec ± 3 sec and the lamp would turn off.
• Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3 LUX, the sensor would not work and
the lamp stop working too. If you cover the detection window with the opaque objects (towel etc), the sensor would work.
Under no induction signal condition, the sensor should stop working within 10 sec ± 3 sec.
Note: when testing in daylight, please turn LUX knob to
(SUN) position, otherwise
the sensor lamp could not work! If the lamp is more than 60W, the distance between lamp
and sensor should be 60cm at least.
SOME PROBLEM AND SOLVED WAY:
• The load do not work:
a. Please check if the connection-wiring of power and load is correct.
b. Please check if the load is good.
c. Please check if the working light sets correspond to ambient light.
• The sensitivity is poor:
a. Please check if there has any hindrance in front of the detection window to affect to receivethe signal.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection fields.
d. Please check if the installation height corresponds to the height showed in the instruction.
e. Please check if the moving orientation is correct.
• The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is the longest.
c. Please check if the power corresponds to the instruction.
IP 20
220-240 V
AC
20
m