Canoga™ Vehicle Detectors
Canoga™ C924X Series Installation Manual
28 – Vehicle Detector Setup & Configuration
Microloop Mode setup are followed, proper operation is expected when an inductive loop
is attached to a channel configured for Microloop operation.
5.2.4.3
Setting Synchronization
Using this feature helps eliminate crosstalk between adjacent loops that are attached to separate
vehicle detectors where rewiring loop inputs into the same vehicle detector is not an option. For
example, loop 1 of vehicle detector A could safely be adjacent to loops 2, 3, or 4 of a different vehicle
detector within the same synchronization group.
Set all units to No Sync or set one unit to Sync Leader and the others units to Sync Follower.
When Sync is used, all 4-channel units will have Channel 1 ON at the same time, next all units will
have Channel 2 ON at the same time, etc. The Scan Time for each unit will be equal to the sum of the
longest channel ON times for each vehicle detector unit being synchronized.
When 2-channel units are mixed with 4-channel units, channel 1 on the 2-channel units will be ON
during the channel 1 time and the channel 3 time on the 4-channel units. Similarly, channel 2 on the
2-channels units will be ON when channel 2 and channel 4 on the 4-channels units is ON.
NOTE: It is mandatory that each channel on every vehicle detector to be synchronized be
connected to an inductive sensor or that the card channel input terminals be shorted.
This applies even for channels that are turned OFF.
When SYNC is programmed, to guarantee that all units are measuring the same channel at the
same time, the
SYNC lines operate as follows:
SYNC 1: Leader unit pulls this line HIGH (+5 VDC) while it is taking a measurement on Channel
1. All followers start a Channel 1 measurement when this line goes HIGH.
SYNC 2: Each unit pulls this line HIGH (to +5 VDC) while it is taking a measurement on any
channel. No unit may proceed to taking a measurement on the next channel until SYNC 2 goes
LOW (to 0 VDC).
Содержание Canoga C924 Series
Страница 1: ...Canoga Traffic Sensing System C924X Series Vehicle Detector Installation Manual January 2013...
Страница 2: ......
Страница 6: ...Canoga Vehicle Detectors Canoga C924X Series Installation Manual iv Table of Contents...
Страница 18: ...Canoga Vehicle Detectors Canoga C924X Series Installation Manual 12 Hardware Installation...
Страница 66: ...Canoga Vehicle Detectors Canoga C924X Series Installation Manual 60 Troubleshooting...